Proliant DL170e G6 QuickSpecs |
US QuickSpecs |
|
|
|
|
|
|
|
|
|
Proliant DL170e G6 Overview
|
HP ProLiant DL2000 Multi Node Server
|
The DL2000 is optimized for efficiency,
density and flexibility and a server node can be serviced individually without
impacting the operation of other server nodes sharing the same chassis.
The DL2000 consists of up to 4 independent DL170e G6 servers in the 2U HP
ProLiant e2000 G6 Chassis. The servers share power supplies and fans, providing
greater power and cooling efficiencies.
The DL2000 was designed to double the density to maximize data center floor
space, increase performance while lowering energy consumption and provide
flexible configurations that fit into existing industry standard racks.
Each DL170e G6 server node supports up to two Intel® two processors
and 16 DDR3 DIMM sockets. The DL170e G6 provides all of the features expected
in an enterprise server, including essential management features (LO100i)
and Easy Setup for rapid deployment, but at a low cost.
|
|
4 Node 24 SFF HDD Model Illustrated
|
|
|
| Front View:
|
Rear View:
|
| 1.
|
1U Node PCIe Riser - Low Profile
PCIe x16 Gen2 Slot
|
1.
|
Common Slot Power Supply
|
| 2.
|
Intel® Xeon® 5500 or 5600 series processors (supports up to two
per node)
|
2.
|
Power supply cable socket
|
| 3.
|
Common Slot Power Supply (two
supported per chassis)
|
3.
|
Low-Profile PCI Express x16 Gen2
slot
|
| 4.
|
4 x 80mm system fans
|
4.
|
Optional dedicated management
port (RJ-45)
|
| 5.
|
Standard Right Power Buttons,
Chassis UID, Health LEDs
|
5.
|
Two USB ports
|
| 6.
|
Standard Left Power Buttons, Health
LEDs
|
6.
|
One GbE LAN port (RJ-45)
|
| 7.
|
16 DDR3 DIMM slots
|
7.
|
One GbE LAN port with shared management
(RJ-45)
|
|
|
|
8.
|
Power Button
|
|
|
|
9.
|
Health LED
|
|
|
|
10.
|
UID Button
|
|
|
|
11.
|
Serial Port
|
|
|
|
12.
|
Video Port
|
|
Standard Features
|
NOTE: For the Standard Features shipped
in the Factory Integrated Models, please see the "Configuration Information
- Factory Integrated Models" section.
|
Processor
One of the following depending on Model
|
Six-Core Processors
|
| Intel® Xeon® X5675 (3.06GHz/6-core/12MB/95W,
DDR3-1333, HT, Turbo 2/2/2/2/3/3) Processor
|
| Intel® Xeon® X5660 (2.80GHz/6-core/12MB/95W,
DDR3-1333, HT, Turbo 2/2/2/2/3/3) Processor
|
| Intel® Xeon® X5650 (2.66GHz/6-core/12MB/95W,
DDR3-1333, HT, Turbo 2/2/2/2/3/3) Processor
|
| Intel® Xeon® E5649 (2.53GHz/6-core/12MB/80W,
DDR3-1333, HT, Turbo 2/2/2/2/3/3) Processor
|
| Intel® Xeon® E5645 (2.40GHz/6-core/12MB/80W,
DDR3-1333, HT, Turbo 2/2/2/2/3/3) Processor
|
| Intel® Xeon® L5640 (2.26GHz/6-core/12MB/60W,
DDR3-1333, HT, Turbo 2/2/3/3/4/4) Processor
|
| Four-Core Processors
|
| Intel® Xeon® E5620 (2.40GHz/4-core/12MB/80W,
DDR3-1066, HT, Turbo 1/1/2/2) Processor
|
| Intel® Xeon® L5630 (2.13GHz/4-core/12MB/40W,
DDR3-1066, HT, Turbo 1/1/2/2) Processor
|
| Intel® Xeon® E5607 (2.26GHz/4-core/8MB/80W,
DDR3-1066) Processor
|
| Intel® Xeon® E5603 (1.60GHz/4-core/4MB/80W,
DDR3-1066) Processor
|
NOTE: HT indicates
that the processor model supports Intel® Hyper-Threading Technology
NOTE: Turbo indicates the maximum potential frequency increment when
using Intel® Turbo Boost Technology, with 6, 5, 4, 3, 2, and 1 cores
active.
NOTE: DDR3 speed is the maximum memory speed of the processor. Actual
memory speed may depend on the quantity and type of DIMMs installed.
NOTE: For the Intel 5000 Series, the letter preceding the model number
indicates the performance/wattage of the processor. "X" denotes
High Performance/Wattage; "E" denotes Enterprise Performance/Wattage
(Mainstream), and "L" denotes Lower Wattage.
NOTE: Up to 2 processors supported. Mixing different processor models
is not supported.
|
|
| Cache Memory
|
12MB (1 x 12MB) Level 3 cache
NOTE: All 5600 processor models except
those noted below.
|
8MB (1 x 8MB) Level 3 cache
NOTE: For processor E5607.
|
6MB (1 x 6MB) Level 3 cache
NOTE: For processor E5603.
|
|
| Upgradeability
|
Upgradeable to two processors
(12 cores)
|
|
| Memory Protection
|
Advanced ECC (multi-bit error
protection)
Mirroring mode
Lockstep mode
|
|
| Memory
|
Type
|
DDR3 Registered (RDIMM) and
Unbuffered (UDIMM)
|
| Maximum (RDIMM) (per server
node)
|
192GB (12 x 16GB) PC3-8500R
(DDR3-800)
|
| Maximum (UDIMM) (per server
node)
|
48GB (12 x 4GB) PC3-10600E (DDR3-1333)
|
| NOTE:
Depending on the memory configuration and processor model, the memory speed
may run at 1333MHz, 1066MHz, or 800MHz. Please see the Online Memory Configuration
Tool at https://www.hp.com/go/ddr3memory-configurator
|
|
| Network Controller
|
HP NC362i Integrated Dual Port
Gigabit Server Adapter
|
|
| Expansion Slots
|
- Half Height Nodes (1U): One available PCI Express Gen 2.0 slots:
- Slot 1: Low profile PCI-Express 2.0 x16
- Full Height Nodes (2U): three available riser options
- Option 1: Up to three available PCI-Express Gen 2.0 slots:
- Slot 1: full-height/full-length PCI-Express 2.0 x16
- Slot 2: full-height/half-length PCI-Express 2.0 x4
- Slot 3: low-profile PCI-Express 2.0 x4
- Option 2: Up to three available PCI-Express Gen 2.0 slots:
- Slot 1: full-height/full-length PCI-Express 2.0 x8
- Slot 2: full-height/half-length PCI-Express 2.0 x8
- Slot 3: low-profile PCI-Express 2.0 x8
- Option 3: Up to two available PCI-Express Gen 2.0 slots:
- Slot 1: full-height/full-length PCI-Express 2.0 x16
- Slot 3: low-profile PCI-Express 2.0 x8
|
| Full-height PCIe
Riser Option
|
Expansion Slots
#
|
Technology
|
Bus
Width
**
|
Connector Width
*
|
Bus
Number
|
Form
Factor
|
Notes
|
| 1
|
PCI-Express 2.0
|
x16
|
x16
|
4
|
Full height, full
length
|
3.3 volts
|
| 2
|
PCI-Express 2.0
|
x4
|
x4
|
6
|
Full height, half
length
|
3.3 volts
|
| 3
|
PCI-Express 2.0
|
x4
|
x4
|
7
|
Low Profile
|
3.3 volts
|
| Full-height PCIe
Riser Option
|
Expansion Slots
#
|
Technology
|
Bus
Width
**
|
Connector Width
*
|
Bus
Number
|
Form
Factor
|
Notes
|
| 1
|
PCI-Express 2.0
|
x8
|
x8
|
4
|
Full height, full
length
|
3.3 volts
|
| 2
|
PCI-Express 2.0
|
x8
|
x8
|
5
|
Full height, half
length
|
3.3 volts
|
| 3
|
PCI-Express 2.0
|
x8
|
x8
|
7
|
Low Profile
|
3.3 volts
|
| Full-height PCIe
Riser Option
|
Expansion Slots
#
|
Technology
|
Bus
Width
**
|
Connector Width
*
|
Bus
Number
|
Form
Factor
|
Notes
|
| 1
|
PCI-Express 2.0
|
x16
|
x16
|
4
|
Full height, full
length
|
3.3 volts
|
| 3
|
PCI-Express 2.0
|
x8
|
x8
|
6
|
Low Profile
|
3.3 volts
|
Half-height PCIe
Riser
(Standard with half-height 1U nodes)
|
Expansion Slots
#
|
Technology
|
Bus
Width
**
|
Connector Width
*
|
Bus
Number
|
Form
Factor
|
Notes
|
| 1
|
PCI-Express 2.0
|
x16
|
x16
|
4
|
Low Profile
|
3.3 volts
|
|
|
* Default
bus assignment. Inserting cards with PCI bridges may alter the actual bus
assignment number.
|
| ** Indicates
the number of physical electrical lanes running to the connector.
|
|
| Storage Controller
|
Non-Hot Plug SATA Models
|
Embedded HP Smart Array Hot
Plug Advanced Pack for B110i (RAID 0, 1, 10)
NOTE: Transfer rate: up to 3 Gb/s
SATA
NOTE: To enable RAID on Embedded SATA (Windows and Linux only), use
the HP Smart Array B110i SATA Raid controller, To enable use of the B110i,
enter the ROM based setup utility(RBSU). The option for enabling RAID can
be found in the advanced section of the RBSU. For additional details www.hp.com/go/SATARAID.
For RAID on Solaris, a Smart Array Controller must be purchased.
|
| Hot Plug SATA Models
|
Embedded HP Smart Array Hot
Plug Advanced Pack for B110i (RAID 0, 1, 10)
NOTE: Transfer rate: up to 3Gb/s
SATA
NOTE: The HP Smart Array B110i SATA Raid Hot Plug Advance Pack provides
the hot-plug and RAID support for the embedded SATA controller. The Hot
Plug Advance kit is a License to enable the RAID support on Hot Plug models.
It supports up to six 3G SATA hard disk drives. It will support a maximum
of two (2) logical drives. It supports Raid 0, 1 and 1+0. For additional
details www.hp.com/go/SATARAID
|
| Hot Plug SAS/SATA Models
|
HP Smart Array Controller RAID
0,1,10, 5
NOTE: Transfer rate: up to 6GB/s
SAS, 3Gb/s SATA
|
NOTE:
SAS Upgrade: A HP Smart Array Controller is required for SAS HDD support.
Transfer rate: 6.0 Gb/s SAS supported.
NOTE: If a Smart Array P410 Controller is added after initial purchase
(e.g. an upgrade) a HP DL170e G6 P410 CONTROLLER CABLE OPTION KIT (P/N 612206-B21)
must be ordered to connect the Smart Array Controller to the adapter board.
NOTE: If any Smart Array Controller other than the P410 is added
after initial purchase (e.g. an upgrade), an HP DL170e G6 SMART ARRAY CONTROLLER
CABLE OPTION KIT (P/N 612207-B21) must be ordered to connect the Smart Array
Controller to the adapter board.
NOTE: An external diskette drive, USB floppy drive key or virtual
FDD using LO100 Advanced Pack is needed to install storage controller drivers
during a Windows operating system installation from a CD.
|
|
| Internal Storage
Devices
|
Diskette Drives
|
Via USB only
|
| Optical Drives
|
DVD drive via USB only (External
support only)
|
Hard Drives
|
None ship standard
|
Drive Bays
One of the following depending on Model
|
Up to 8 or 12 Hot plug SAS/SATA
3.5" drives
|
| Up to 16 or 24 Hot plug SAS/SATA
2.5" drives
|
| NOTE: The 12
LFF HDD cage is available for special large volume configurations only.
Please contact your HP representative for details.
|
|
| Maximum Internal
Storage
|
LFF 3.5" Hot Plug SATA
|
24.0TB
|
8 x 3TB
*
|
| LFF 3.5" Hot Plug SAS
|
24.0TB
|
8 x 3TB
|
| LFF 3.5" Hot Plug SATA
|
36.0TB
|
12 x 3TB
*
|
| LFF 3.5" Hot Plug SAS
|
36.0TB
|
12 x 3TB
|
| SFF 2.5" Hot Plug SATA
|
16.0TB
|
16 x 1TB
|
| SFF 2.5" Hot Plug SAS
|
16.0TB
|
16 x 1TB
|
| SFF 2.5" Hot Plug SATA
|
24.0TB
|
24 x 1TB
|
| SFF 2.5" Hot Plug SAS
|
24.0TB
|
24 x 1TB
|
| NOTE:
The 12 LFF HDD cage is available for special large volume configurations
only. Please contact your HP representative for details.
|
| NOTE:
To support HP hard drives exceeding 2.2 TB, a HP Smart Array Controller
is required.
|
|
| Interfaces
|
Serial
|
1
|
| Network RJ-45 (Ethernet)
|
2 10/100/1000 NIC ports (1 NIC
shared for the HP ProLiant Lights Out 100i Remote Management)
|
Graphics
|
1
|
| Management
|
1 Optional Dedicated LO100i
Management Port
|
Health LED
|
2 (1 front and 1 rear) per server
node
|
Power
|
2 (1 front and 1 rear) per server
node
|
UID
|
1 rear per server node and 1
upfront system UID
|
| USB
|
3 (two rear, one internal)
|
|
| Industry Standard
Compliance
|
ACPI V2.0 Compliant
|
| PCI 2.2 Compliant
|
| PXE Support
|
| WOL Support
|
| Microsoft® Logo certifications
|
| IPMI 2.0, DCMI 1.0. SMASH CLP
compliant
|
|
| Graphics
|
Integrated Matrox Graphics G200e, 32MB Standard
- 16 bit color: maximum resolution of 1600 x 1200
- 32 bit color: maximum resolution of 1280 x 1024
|
|
The following NVIDIA graphics cards are tested for compatibility in the
DL2000 (when using full-height 2U nodes):
- NVIDIA Quadro 6000 6GB PCIe x 16 graphics card
- NVIDIA Quadro FX5800 4GB PCIe x 16 graphics card
- NVIDIA Quadro 4000 2GB PCIe x 16 graphics card
- NVIDIA Quadro FX3800 1GB PCIe x 16 graphics card
NOTE: For more information on
the latest visualization and acceleration qualification status, please
see https://www.hp.com/go/accelerators
NOTE: An HP DL170e GPU Adapter Kit (P/N 612253-B21) is required
when installing this NVIDIA card. The NVIDIA cards can only be installed
in the 2U node with the 2 slot full-height riser option: HP DL170e I/O
Riser PCIe x16 x8 FIO option (P/N 512481-B21).
|
|
| Server Power Cords
|
One 6' Highline (IEC-IEC) power cord ships standard
NOTE: HP ProLiant DL servers are
primarily connected to PDU's in data center racks so they ship standard
with only a PDU power cord (416151-B21).
NOTE: If customers require a power cord, they can check the power
cord matrix for the appropriate cord. Please see the following power cord
matrix: https://www.hp.com/go/powercordmatrix
|
|
| Advanced Power Management: Power
Management Controller
|
In addition to the efficiencies gained by the shared power infrastructure,
the DL2000 contains advanced power metering and capping capabilities.
The embedded Power Management Controller (PMC) is able to monitor power
consumption and throttle the speed of the processors and memory in each
node within the chassis in order to maintain a pre-set power budget. HP
provides a simple command-line utility, called HP ProLiant Power Interface
Control (PPIC) Utility, for reading and configuring the power control
logic of the server nodes. Versions are available for MS Windows Server
OS (2008 and 2008 R2) and Linux OS (RHEL5 and SLES11) with the requirement
that the OS IPMI Driver be installed. The following Power Management modes
for power redundancy are standard and are configurable in the controller:
- No Redundancy - power control disabled. No power throttling will occur.
- (DEFAULT) AC Redundancy with Throttling. This mode allows all nodes
to share both power supplies and run at maximum performance. Power control
logic will only throttle the performance of each node when the power
draw by the chassis attempts to exceed the load supported by the power
supplies. In this mode, the box is expected to survive an unexpected
AC Power loss to one of the power supplies.
- Full AC/DC Redundancy - power control logic will maintain a power
cap value for the chassis at the DC rating of a single power supply
(750W, or 1200W), such that if one power supply experiences a DC or
AC failure, the chassis should remain on-line and operational.
Power Capping is included with the LO100 Advanced Pack:
- Power Capping - User specifies the power envelope for the 2U chassis,
within the capabilities of the hardware installed. Users run a utility
to calibrate the minimum and maximum power consumption envelope for
the chassis. In order to avoid any impact to performance due to throttling,
a User selectable Power Cap value should not be set below the minimum
power value provided by the utility.
|
|
| Power Supply
|
HP has a new design for ProLiant power supplies - the new Common Slot
power supply bay. This design provides the customer with commonality in
power supplies across multiple platforms to save on the cost of spares
and allows HP to offer multiple power solutions to fit the customers'
needs. Many HP ProLiant Servers come with high-efficiency Common Slot
power supplies. The new HP Common Slot power supplies are designed for
the highest power efficiency without degrading performance of the ProLiant
server. These power supplies have efficiency ratings up to 94%. There
are multiple power supply options available allowing you to "right-size"
the most appropriate power supply for your server configuration. To make
sure you select the correct power supply to meet your configuration, please
use the HP Power Advisor at: www.hp.com/go/hppoweradvisor.
All HP Common Slot power sources are UL, CE mark compliant, hot-plug,
and support Redundant Power Management: In addition to the shared power
and cooling infrastructure, the DL2000 contains advanced power metering
and power capping technologies. The Power Interface Controller allows
you to configure the system for full AC redundancy or AC redundancy with
power throttling, depending on your configuration. With the optional Dynamic
Power Capping mode, the DL2000 can boost the capacity of your data center
by reclaiming trapped power and cooling capacity.
HP offers several Common Slot Power Supply Options for this platform.
NOTE: The 80 PLUS program is a
unique forum that unites electric utilities, the computer industry, and
consumers in an effort to bring energy efficient technology solutions
to the marketplace. 80 Plus independently tests power supply efficiency
and publicly posts the results on 80Plus.org.
Optional power supplies can be purchased through power supply option kits
(see Power Supply Options for part numbers).
NOTE: Mixing of power supplies in the same chassis is not supported.
All power supplies must be of the same type, all, 750W 94%, all 1200W
94%, or all 1200W 90%. If non-matched power supplies are inserted you
will get errors and operation will fail.
|
|
| System Fans
|
4 x 80mm system fans ship standard; Non-hot plug, Non-redundant.
|
|
| Form Factor
|
HP ProLiant e2000 G6 Chassis - 2U Chassis can support up to four DL170e
server nodes in the 2U chassis.
|
| HP ProLiant DL170e G6 Server
- Half-width system board. Half-height (1U) or full-height (2U) depending
on riser option selected.
|
|
HP offers four different drive cages for the 2U HP ProLiant e2000 G6
Chassis
- 8 LFF HDD Cage
- 12 LFF HDD Cage
NOTE: Available for special large
volume configurations only. Contact HP representative)
- 16 SFF HDD Cage
- 24 SFF HDD Cage
The 2U chassis can support two server node configurations:
- Two full height nodes
- Four half-height nodes
Server Node Blanks
If a server node is removed for a period, a blank must be installed to
maintain the thermal environment in the chassis. It is okay to leave a
node in the chassis powered off to be serviced in the future. But once
a DL170e node is removed for servicing, a HP DL2000 Server Node Blank
Kit is required. The blank is a 1U blank so two blanks are needed for
a 2U node.
|
|
4 Node Configuration - Front View
|
|
|
| NOTE: For 2
node configurations, 2U nodes are ordered and are numbered 1 and 3. NOTE:
Additional nodes cannot be added later to 2 node configurations.
|
|
| Embedded Manageability
|
HP ProLiant Lights-Out 100
|
HP Lights-Out 100 with Optional LO100 Advanced Licenses for Virtual KVM
and Virtual Media.
Standard Features:
- IPMI 2.0, DCMI 1.0, and SMASH CLP support
- Configuration via ROM Setup Utility or LO100cfg utility
- USB 2.0 support for virtual media for much faster transfer speeds
- Enhanced browser interface and embedded KVM over IP provides OS-independent
remote graphical console
- 24x7 Technical Support and Update (TSU) 1 year support and license
upgrades included in Advanced license
For more information, see: www.hp.com/go/lo100.
|
|
| Security
|
Power-on password
|
| Setup password
|
|
Diskette boot control
|
| Secure Sockets Layer (SSL)
|
| Secure Shell (SSH)
|
|
| Warranty
|
This product is covered by a global limited warranty and supported by
HP Services and a worldwide network of HP Authorized Channel Partners.
Hardware diagnostic support and repair is available for one year from
date of purchase. Support for software and initial setup is available
for 90 days from date of purchase. Enhancements to warranty services are
available through HP Care Pack services or customized service agreements.
Hard drives have either a one year or three year warranty; refer to the
specific hard drive QuickSpecs for details.
NOTE: Server Warranty includes
1 year Parts, 1 year Labor, 1-year on-site support with next business
day response. Warranty repairs may be accomplished through the use of
Customer Self Repair (CSR) parts. These parts fall into two categories:
1) Mandatory CSR parts are designed for easy replacement. A travel and
labor charge will result when customers decline to replace a Mandatory
CSR part; 2) Optional CSR parts are also designed for easy replacement
but may involve added complexity. Customers may choose to have HP replace
Optional CSR parts at no charge. Additional information regarding worldwide
limited warranty and technical support is available at: https://h18004.www1.hp.com/products/servers/platforms/warranty/index.html.
|
Optional Features
| HP Insight management
|
HP Insight Control
|
HP Insight Control, a product option, delivers essential infrastructure
management that can help save time and money by making it easy to deploy,
migrate, monitor, remote control, and optimize your IT infrastructure
through a single, simple management console. For more information, see
https://www.hp.com/go/insightcontrol.
HP Insight Control includes one year of 24 x 7 HP Software Technical
Support and Update Service ensuring rapid access to HP support staff and
proactive delivery of software updates. For more information about this
service, see: https://www.hp.com/services/insight.
|
| HP Insight Control server deployment
|
HP Insight Control server deployment
is a deployment solution for HP ProLiant and Integrity servers hosted on
a Windows CMS. It automates the process of deploying and provisioning server
software, enabling companies to quickly and easily adapt to changing business
demands. Insight Control server deployment includes software optimizations
for HP servers, including the HP scripting toolkits, configuration jobs
for leading industry-standard operating systems, sample unattended files,
and HP server support packs that include software drivers, management agents,
and important documentation. Deploying servers can be accomplished either
through imaging or through scripting.
Insight Control server deployment is hosted on a Windows server and is intended
for heterogeneous environments deploying Windows, Linux, VMware ESX and
Microsoft Hyper-V systems.
Insight Control server deployment includes one year of 24 x 7 HP Software
Technical Support and Update Service ensuring rapid access to HP support
staff and proactive delivery of software updates. For more information about
this service, please visit: https://www.hp.com/services/insight.
|
|
| Core Server Management
|
ProLiant 100 Series G6 Core
Management Software for ProLiant 100 Series Servers
|
HP provides management solutions that are designed to simplify a server's
installation, configuration, and maintenance throughout the entire server
lifecycle. This provides the customers with higher levels of operational
efficiency and highly reliable systems.
While ProLiant 100 series G6 servers do not support the Insight Foundation
Suite for ProLiant, they support a key subset of this important suite
software tools and utilities which are very suitable for this class of
server: SIM, SMH, agents, providers, and a SmartStart 'like' deployment
capability called Easy Set-up which greatly simplifies server set-up.
Additionally the DL100 and SL100 G6 models support the SmartStart Scripting
Toolkit (SSSTK), an automated scalable deployment utility.
Information on core management supported on ProLiant 100 series G6 servers
can be found at these URLS:
|
|
| Core Infrastructure
Management
|
HP Systems Insight Manager
|
HP Systems Insight Manager (HP SIM) provides a unified, secure and extensible
standards-based environment to centrally manage servers, storage and other
infrastructure devices, (both HP and non-HP) across multiple operating
system platforms.
|
| Insight Management Agents
|
HP Insight Management Agents and Insight Management Providers are available
for HP Systems Insight Manager (SIM) Integration.
ProLiant 100-series G6 servers can use the same SNMP based Insight Management
Agents supported by other ProLiant servers. As a result, administrators
can use HP Systems Insight Manager (SIM) 5.3 and greater to manage ProLiant
100-series G6 servers. Administrators can also use any other SNMP- based
management tool. These agents are obtained as part of the ProLiant 100-series
model-specific "Easy Set-up" CDs, or through https://www.hp.com/servers/easysetup
The following capabilities are enabled on the 100-series G6 servers by
the SNMP agents:
- Health monitoring capabilities, including monitoring for drives, fans,
network, power supplies, and temperature
- Alerting capabilities, including basic alert notification for Smart
Array drive pre-failure only
- Performance monitoring capabilities providing information on processor,
memory, disk free space, network utilization
For additional information, please see: https://www.hp.com/go/insight
|
| Easy Set-up
|
Easy Set-up is available for this platform as an ISO image web download.
HP ProLiant Easy Set-up provides easy, step-by-step, single and multi-server
server utilities to streamline server setup. The user experience is consistent
with SmartStart and offers the following capabilities:
- Boot environment and GUI
- Assisted Installation: Windows 2003 Server and Windows 2008 Server
drivers
- Manual installation: Windows 2003 Server, Windows 2008 Server, and
Linux drivers (specific OS support varies by server. Refer to each server's
QuickSpecs for supported versions)
- HP Insight Diagnostics
- AutoRun
- Array Configuration Utility (ACU) has been combined with Array Diagnostics
Utility (ADU) to offer both configuration of array controllers and storage
devices and testing of array controller hardware
- SmartStart Scripting Toolkit (SSSTK) and Smart Components for software
and drivers
NOTE: OS and SW available for Manual
Installation are listed on each servers' QuickSpecs.
|
| SmartStart Scripting Toolkit
(SSSTK)
|
The SmartStart Scripting Toolkit
is a server deployment product that delivers an unattended automated installation
for high-volume server deployments. The SmartStart Scripting Toolkit includes
a set of utilities for configuring and deploying servers in a customized,
predictable, and unattended manner. These utilities enable you to duplicate
the configuration of a source server on target servers with minimum user
interaction.
The Toolkit is designed for IT experts with experience in scripting operating
system installations and configuring ProLiant server hardware.
For additional information, please see: https://h18004.www1.hp.com/products/servers/management/toolkit/
index.html
|
| Subscriber's Choice
|
Subscriber's Choice Driver and
Support Alerts/Notifications is a web-based email subscription service that
provides software and driver change notifications for ProLiant products.
Sign up at: https://www.hp.com/go/subscriberschoice
and customize your profile to receive various new alerts as they become
available, on a weekly or monthly basis.
|
| ROMPaq, software and latest
drivers
|
The latest software, drivers, and firmware fully optimized and tested
for your ProLiant server and options; downloaded from Software and Drivers
download pages website at: https://www.hp.com/go/support
and from www.hp.com/servers/easysetup.
Contains the following:
- HP Insight Management Agents for Systems Insight Manager (SIM) Integration
- HP Systems Management Homepage
- Array Configuration Utility (ACU)
- Array Diagnostics Utility (ADU)
- HP Insight Diagnostics
|
|
| High
Performance Clusters
|
HP Cluster
Platforms
|
HP Cluster Platforms
are specifically engineered, factory-integrated large-scale ProLiant clusters
optimized for High Performance Computing, with a choice of servers, networks and
software. Operating system options include specially priced offerings for Red
Hat Enterprise Linux and Novell SLES, as well as Microsoft Windows HPC Server.
A Cluster Platform Configurator simplifies ordering. https://www.hp.com/go/clusters
|
| HP HPC Interconnects
|
High Performance Computing (HPC) interconnect technologies are available for
this server as part of the HP Cluster Platform portfolio. These high-speed InfiniBand
and Gigabit interconnects are fully supported by HP when integrated within an
HP cluster. Flexible, validated solutions can be defined with the help of configuration
tools. https://www.hp.com/techservers/clusters/ucp/index.html
|
| HP Cluster Management Utility
|
HP Cluster Management Utility (CMU) is an HP-licensed and HP-supported suite
of tools that are used to manage large-scale Linux ProLiant systems. CMU includes
software for the centralized provisioning, management and monitoring of nodes.
CMU makes the administration of clusters user friendly, efficient, and effective.
https://www.hp.com/go/cmu
|
|
| Storage Software
|
Whether you need to solve a specific data protection, archiving, or storage
command and control challenge, or deliver on strategic consolidation,
compliance, or continuity initiatives, look no further than HP storage
software. Our storage software helps you reduce costs, simplify storage
infrastructure, protect vital assets and respond faster to business opportunities.
Storage software that gets the job done:
- Data Protection and Recovery Software
Whether you're a large enterprise or a smaller business, HP data protection
and recovery software will cost-effectively protect you against disaster
and ensure business continuity.
- Data Archive and Migration Software
HP's storage software enables you to comply with data retention and
retrieval requirements, improve application performance, and reduce
costs by efficiently migrating infrequently accessed or less valuable
data to lower cost storage.
- Storage Resource Management Software (SRM)
HP's storage resource management software reduces operational costs
and provides the command and control foundation you need to efficiently
manage and visualize your physical and virtual environments.
- Data Replication Software
HP offers array-based and host-based replication software for use in
disaster recovery, testing, application development and reporting.
- Storage Device Management Software
Maximize your investment in HP storage and networking with software
that enables hardware-specific configuration, performance tuning and
connectivity management.
- HP StoreVirtual VSA
With HP StoreVirtual VSA you can use the power of virtualization to
turn a set of heterogeneous and disconnected physical disk drives in
your servers and storage devices into a single pool of logical storage
capacity.
NOTE: For more information available
Storage Software including QuickSpecs, please see:
www.hp.com/go/storage/software.
|
|
| Factory Express Portfolio for
Servers and Storage
|
HP Factory Express offers configuration, customization, integration and
deployment services for HP servers and storage products. Customers can
choose how their factory solutions are built, tested, integrated, shipped
and deployed.
Factory Express offers service packages for simple configuration, racking,
installation, complex configuration and design services as well as individual
factory services, such as image loading, asset tagging, and custom packaging.
HP products supported through Factory Express include a wide array of
servers and storage: HP Integrity, HP ProLiant, HP ProLiant Server Blades,
HP BladeSystem, HP 9000 servers as well as the MSAxxxx, VA7xxx, EVA, XP,
rackable tape libraries and configurable network switches.
For more information on Factory Express services for your specific server
model please contact your sales representative or go to: https://www.hp.com/go/factory-express.
|
|
| HP Simple Configurator
|
SCE is a guided self service tool to help sales and non technical people
provide customers with initial configurations in 3 to 5 minutes. You may
then send the configuration on for configuration help, or use in your
existing ordering processes. If you require "custom" rack configuration
or configuration for products not available in SCE, please contact HP's
Customer Business Center or an Authorized Partner for assistance. https://www.hp.com/products/configurator
|
Service and Support
| Service and Support
|
HP Technology Services for Industry Standard Servers and BladeSystem
Capitalizing on HP ProLiant server and HP BladeSystem capabilities requires
a service partner who understands your increasingly complex business technology
environment. That's why it makes sense to team up with the people who
know HP infrastructure hardware and software best - the experienced professionals
at HP Services.
What HP ProLiant and BladeSystem Services can do for you
HP ProLiant and BladeSystem Services can help you design, deploy, test,
integrate, support, and manage IT and infrastructure solutions. This way,
HP proposes services solutions that include more than just uplift of base
warranty. You can get the support you need by choosing from one of a number
of service packaged solutions we have designed to address wider set of
customer support needs:.
HP Technology Services meets business challenges with services offered
in three packages - Optimized Care Package, Standard Care Package,
and Basic Care Package - available for each product group. Such packaged
solutions enable customers to optimize technology operations, minimize
risk and drive better business outcomes with easy-to-buy, easy-to-use
scalable support packages for servers, storage, networking and software.
|
|
| Optimized Care
|
Optimized Care Package: Supports
maintaining servers at optimum performance availability
HP ProLiant Server Hardware Installation
Provides for the basic hardware installation of HP branded servers, storage
devices and networking options to assist you in bringing your new hardware
into operation in a timely and professional manner. https://h20195.www2.hp.com/V2/GetPDF.aspx/5981-9356EN
HP Installation and Startup for Insight Control Software
Provides for the deployment and basic configuration of HP Insight Control
on HP ProLiant ML and DL series servers or HP BladeSystem servers.
https://h20195.www2.hp.com/v2/GetPDF.aspx/4AA0-9972ENW.pdf
3-Year HP Critical Advantage
Provides end-to-end infrastructure support solution for business critical
applications running on virtualized/x86 infrastructures, enabling the customers
to cost effectively build, operate, and continuously improve their IT environment.
https://h20195.www2.hp.com/V2/GetDocument.aspx?docname=4AA3-1772ENW
Additional Services: Microsoft or Linux or VMware education courses
+ Facility & technology environmental assessment services + Energy Efficiency
Design, Factory Express
|
|
| Standard Care
|
Standard Care Package: Package
that maintains high level of server availability
HP ProLiant Server Hardware Installation
Provides for the basic hardware installation of HP branded servers, storage
devices and networking options to assist you in bringing your new hardware
into operation in a timely and professional manner
https://h20195.www2.hp.com/V2/GetPDF.aspx/5981-9356EN
HP Installation and Startup for Insight Control Software
Provides for the deployment and basic configuration of HP Insight Control
on HP ProLiant ML and DL series servers or HP BladeSystem servers
https://h20195.www2.hp.com/v2/GetPDF.aspx/4AA0-9972ENW.pdf
3-Year HP 6 hour Hardware Support Onsite Call-to-Repair Service
Provides an IT manager with a team of support specialists who will quickly
begin troubleshooting the system to help return the hardware to operating
condition within 6 hours of the initial service request to the HP Global
Solution Center
https://h20195.www2.hp.com/V2/GetPDF.aspx/5982-6547EN.pdf
3-Year , HP 24x7 Software Support for Insight Control
Provides for the deployment and basic configuration of HP Insight Control
on HP ProLiant ML and DL series servers or HP BladeSystem servers
https://h20195.www2.hp.com/V2/GetPDF.aspx/5981-6645EEE.pdf
Additional Services: Software OS (Microsoft, Linux (SUSE/Red Hat)
& VMware Installation & Start Up, and Software Support; Install
and Startup Services for Insight Control; Microsoft or Linux or VMware education
courses; +30 Proactive Select Credits, Factory Express
|
|
| Basic Care
|
Basic Care Package: delivers minimum recommended support service level
HP ProLiant Server Hardware Installation
Provides for the basic hardware installation of HP branded servers, storage
devices and networking options to assist you in bringing your new hardware
into operation in a timely and professional manner
https://h20195.www2.hp.com/V2/GetPDF.aspx/5981-9356EN
HP Installation and Startup for Insight Control Software
Provides for the deployment and basic configuration of HP Insight Control
on HP ProLiant ML and DL series servers or HP BladeSystem servers
https://h20195.www2.hp.com/v2/GetPDF.aspx/4AA0-9972ENW.pdf
3-Year HP 24x7 4 hour Response, Hardware Support Onsite Service
Provides for the deployment and basic configuration of HP Insight Control
on HP ProLiant ML and DL series servers or HP BladeSystem servers
https://h20195.www2.hp.com/v2/GetPDF.aspx/4AA0-9972ENW.pdf
3-Year , HP 24x7 Software Support for Insight Control
Provides for the deployment and basic configuration of HP Insight Control
on HP ProLiant ML and DL series servers or HP BladeSystem servers
https://h20195.www2.hp.com/V2/GetPDF.aspx/5981-6645EEE.pdf
Additional Services: Software OS (Microsoft, Linux (SUSE/Red Hat)
& VMware Installation & Start Up and Software Support); +10 Proactive
Select Credits, Factory Express
|
|
| Insight Remote Support
|
The packages include HP Insight Remote Support that uses proven technology
to deliver secure, reliable 24x7 remote monitoring, diagnoses, and problem
resolution. It is available at no additional cost to all warranty, HP
Care Pack Service, and service agreement customers.
|
|
| For more information
|
To learn more on HP ProLiant servers and HP BladeSystem servers, please
contact your HP sales representative or HP Authorized Channel Partner.
Or visit: https://www.hp.com/services/proliant
|
Configuration Information - Factory Integrated Models
|
NOTE: This section lists some of the steps required to configure
a Factory Integrated Model. To ensure only valid configurations are ordered,
HP recommends the use of an HP approved configurator. Contact your local
sales representative for information on configurable product offerings
and requirements.
NOTE: Configure-to-order (CTO) servers must start with a CTO Chassis.
NOTE: FIO indicates that this option is only available as a factory
installable option.
|
| Step
1: Base Configuration (choose one from each list unless otherwise noted)
|
| HP Chassis
|
HP ProLiant e2000
G6 Configure-to-order Chassis
|
609326-B21
|
| HP Drive Cage Options
|
HP 8 LFF DL2000 FIO Hard Drive
Cage with Backplane Kit
|
611431-B21
|
| HP 12 LFF Hard Drive Cage/Backplane
DL2000 FIO Kit
|
611432-B21
|
| HP 16 SFF Hard Drive Cage/Backplane
DL2000 FIO Kit
|
611433-B21
|
HP 24 SFF Hard Drive Cage/Backplane
DL2000 FIO Kit
|
611434-B21
|
| NOTE: for configurations
with the 12 LFF HDD Cage, please contact your HP representative.
|
|
| HP Rail Kits
|
HP DL2000 Hardware Rail Kit
NOTE: 2U rail kit used for HP or
3rd party racks - allows addition of one e2000 chassis at a time.
|
611428-B21
|
HP 10U Bulk Rail 2U
Kit
NOTE: 10U rail kit used for HP racks
ONLY - allows addition of five e2000 chassis at a time.
|
612901-B21
|
| HP Drive Cage Cable Kits
|
NOTE: Required
Drive Cage Cable kits for the DL2000. These cables connect the midplane
to the drive backplane and are based on the drive cage used and the number
of nodes.
|
|
| 2 Node 8LFF Configurations
- order the following cables to connect the midplane to the drive backplane:
|
|
HP Mini-SAS to SATA 20/25/29cm
FIO Cable Kit
NOTE: Quantity 1 per chassis.
|
612256-B21
|
HP Mini-SAS to SATA 25/20/29cm
FIO Cable Kit
NOTE: Quantity 1 per chassis.
|
612257-B21
|
HP Mini-SAS to SAS 160mm A FIO
Cable Kit
NOTE: Quantity 1 per chassis.
|
630874-B21
|
HP Mini-SAS to Mini-SAS
33cm FIO Cable Kit
NOTE: Quantity 1 per chassis.
|
612255-B21
|
| 2 Node 16SFF Configurations
- order the following cables to connect the midplane to the drive backplane:
|
|
HP Mini-SAS to Mini-SAS 25cm FIO
Cable Kit
NOTE: Quantity 1 per chassis.
|
612254-B21
|
HP Mini-SAS to Mini-SAS 33cm FIO
Cable Kit
NOTE: Quantity 2 per chassis.
|
612255-B21
|
HP Mini-SAS 45cm FIO Cable Kit
NOTE: Quantity 1 per chassis.
|
625805-B21
|
2 Node 24 SFF Configurations
- order the following cables to connect the midplane to the drive backplane:
|
|
HP Mini-SAS to Mini-SAS 25cm FIO
Cable Kit
NOTE: Quantity 4 per chassis.
|
612254-B21
|
HP Mini-SAS to Mini-SAS 33cm FIO
Cable Kit
NOTE: Quantity 3 per chassis.
|
612255-B21
|
HP Mini-SAS 45cm FIO Cable Kit
NOTE: Quantity 1 per chassis.
|
625805-B21
|
4 Node 8LFF Configurations
- order the following cables to connect the midplane to the drive backplane:
|
|
HP Mini-SAS to SAS/SATA E FIO
Cable Kit
NOTE: Quantity 2 per chassis.
|
630870-B21
|
HP Mini-SAS to SAS/SATA F FIO
Cable Kit
NOTE: Quantity 2 per chassis.
|
630872-B21
|
4 Node 16SFF Configurations
- order the following cables to connect the midplane to the drive backplane:
|
|
HP Mini-SAS to Mini-SAS 25cm FIO
Cable Kit
NOTE: Quantity 1 per chassis.
|
612254-B21
|
HP Mini-SAS to Mini-SAS 33cm FIO
Cable Kit
NOTE: Quantity 3 per chassis.
|
612255-B21
|
4 Node 24 SFF Configurations
- order the following cables to connect the midplane to the drive backplane:
|
|
HP Mini-SAS to Mini-SAS 25cm FIO
Cable Kit
NOTE: Quantity 4 per chassis.
|
612254-B21
|
HP Mini-SAS to Mini-SAS 33cm FIO
Cable Kit
NOTE: Quantity 3 per chassis.
|
612255-B21
|
HP Mini-SAS 45cm FIO Cable Kit
NOTE: Quantity 1 per chassis.
|
625805-B21
|
| HP Power Supplies
|
NOTE: Prior to
making a power supply selection it is highly recommended that the HP Power
Advisor is run to determine the right size power supply for your server
configuration. The HP Power Advisor is located at: www.hp.com/go/hppoweradvisor
|
|
| HP 750W Common Slot
Platinum Hot Plug Power Supply Kit
|
593831-B21
|
HP 1200W Common Slot Platinum
Hot Plug Power Supply Kit
|
578322-B21
|
HP 1200W Common Slot Silver Hot
Plug Power Supply Kit
|
500172-B21
|
| Step 1A: Choose
Required Nodes (Must select either a 4-Node or 2-Node solution)
|
| HP Nodes
|
HP ProLiant DL170e G6 Node 1U
Configure-to-order Server
|
609095-B21
|
| HP ProLiant DL170e G6 Node 2U
Configure-to-order Server
|
609096-B21
|
|
| Step
2: Choose Required Node Options (only one of the following from each list unless
otherwise noted)
|
|
HP Processors
|
NOTE:
If 2 processors are desired, select one xxxxxx-L21 and one xxxxxx-B21
|
|
| Six-Core Processors
|
|
| HP DL170e G6 Intel®
Xeon® X5675 (3.06GHz/6-core/12MB/95W) FIO Processor Kit
|
638021-L21
|
| HP DL170e G6 Intel®
Xeon® X5660 (2.80GHz/6-core/12MB/95W) FIO Processor Kit
|
609142-L21
|
| HP DL170e G6 Intel®
Xeon® X5650 (2.66GHz/6-core/12MB/95W) FIO Processor Kit
|
609140-L21
|
| HP DL170e G6 Intel®
Xeon® E5649 (2.53GHz/6-core/12MB/80W) FIO Processor Kit
|
638019-L21
|
| HP DL170e G6 Intel®
Xeon® E5645 (2.40GHz/6-core/12MB/80W) FIO Processor Kit
|
638017-L21
|
| HP DL170e G6 Intel®
Xeon® L5640 (2.26GHz/6-core/12MB/60W) FIO Processor Kit
|
609132-L21
|
| Quad-Core Processors
|
|
| HP
DL170e G6 Intel® Xeon® E5620 (2.40GHz/4-core/12MB/80W) FIO Processor Kit
|
609136-L21
|
| HP DL170e G6 Intel®
Xeon® L5630 (2.13GHz/4-core/12MB/40W) FIO Processor Kit
|
612468-L21
|
| HP
SL160s G6 Intel® Xeon® E5607 (2.26GHz/4-core/8MB/80W) FIO Processor Kit
|
638015-L21
|
| HP DL170e G6 Intel®
Xeon® E5603 (1.60GHz/4-core/4MB/80W) FIO Processor Kit
|
638013-L21
|
|
| HP Memory
|
Registered
DIMMs (RDIMMs)
|
|
| HP 2GB (1x2GB) Dual
Rank x8 PC3-10600 (DDR3-1333) Registered CAS-9 Memory Kit
|
500656-B21
|
| HP 4GB (1x4GB) Dual
Rank x4 PC3-10600 (DDR3-1333) Registered CAS-9 Memory Kit
|
500658-B21
|
| HP 4GB (1x4GB) Single
Rank x4 PC3-10600 (DDR3-1333) Registered CAS-9 Memory Kit
|
593339-B21
|
HP 4GB (1x4GB) Single
Rank x4 PC3L-10600 (DDR3-1333) Registered CAS-9 Low Power Memory Kit
NOTE:
Low Voltage DIMMs can only be used with Intel® Xeon® processor 5600 series processors.
|
604504-B21
|
| HP 16GB (1x16GB)
Quad Rank x4 PC3-8500 (DDR3-1066) Registered CAS-7 Memory Kit
|
500666-B21
|
| HP 8GB (1x8GB) Dual
Rank x4 PC3-10600 (DDR3-1333) Registered CAS-9 Memory Kit
|
500662-B21
|
HP 8GB (1x8GB) Dual
Rank x4 PC3L-10600 (DDR3-1333) Registered CAS-9 Low Power Memory Kit
NOTE:
Low Voltage DIMMs can only be used with Intel® Xeon® processor 5600 series processors.
|
604506-B21
|
Unbuffered with
ECC DIMMs (UDIMMs)
NOTE: Maximum 12
DIMMs supported per node.
|
|
| HP 2GB (1x2GB) Dual
Rank x8 PC3-10600 (DDR3-1333) Unbuffered CAS-9 Memory Kit
|
500670-B21
|
| HP 4GB (1x4GB) Dual
Rank x8 PC3-10600 (DDR3-1333) Unbuffered CAS-9 Memory Kit
|
500672-B21
|
| HP 4GB (1x4GB) Dual
Rank x8 PC3L-10600 (DDR3-1333) Unbuffered CAS-9 Low Power Memory Kit
|
619488-B21
|
NOTE:
All DDR3 memory option kits consist of one DIMM per kit. For detailed memory configuration
rules and guidelines, please use the Online DDR3 Memory Configuration Tool: www.hp.com/go/ddr3memory-configurator.
NOTE: Kits described as LV include Low Power DIMMs. For more information
on ProLiant Energy Efficient Features, see: www.hp.com/go/proliant-energy-efficient
NOTE: PC3L is a low voltage memory.
|
|
|
NOTE:
There is a maximum support limitation of 8 ranks per memory channel (maximum of
2 quad rank DIMMs per channel)
NOTE: Memory Min and Max depends on
number of processors and type of memory:
- Processor -> R-Dimm: Min
1 // Max 8 U-Dimm: Min 1 // Max 6
- Processors -> R-Dimm: Min 2 // Max 16
U-Dimm: Min 2 // Max 12
|
|
|
| HP I/O Expansion
Options
|
Full-height
(Only required if PN: 609096-B21 is selected in Step 1A above)
|
|
| HP DL170h Input/Output
PCIex16x4x4 FIO Riser Kit
|
514005-B21
|
| HP DL170h Input/Output
PCIe x8x8x8 FIO Riser Kit
|
503587-B21
|
HP DL170h Input/Output
PCIe x16x8 FIO Riser Kit
NOTE: The
2 slot riser (P/N: 512481-B21) is the only riser option that supports the NVIDIA
graphics cards.
|
512481-B21
|
|
| Step 3: Choose Additional
Factory Integratable Options (only one of the following from each list unless
otherwise noted)
|
| HP Storage Controllers
|
NOTE: Non-Hot-Plug
SATA Models: The embedded HP Smart Array B110i SATA RAID supports RAID 0,1,10
and cold-plug capability with hot-plug form factor drives. Non-hot-plug
form factor hard disk drives are not supported in the DL2000.
NOTE: Hot-Plug SATA Models: A HP Smart Array B110i SATA RAID Hot-Plug
Advanced Pack per server or virtual machine is required for hot-plug SATA
using the embedded B110i SATA RAID controller.
NOTE: Supported controllers vary by configuration. See table below
for supported controllers. For a complete list of HP Storage controllers,
please see the Additional Options section of this QuickSpecs. Only FIO options
are mentioned here.
|
|
| Configuration
|
Supported Controllers
|
| 4x1U nodes with 8LFF HDD cage (2 HDDs/node
max)
|
Embedded (SATA only) or
P410 (SATA/SAS)
|
| 4x1U nodes with 16SFF HDD cage (4 HDDs/node
max)
|
Embedded (SATA only) or
P212 or P410 (SATA/SAS)
|
| 4x1U nodes with 24SFF HDD cage (6 HDDs/node
max)
|
Embedded (SATA only) or
P410 (SATA/SAS)
|
| 2x2U nodes with 8LFF HDD cage (4 HDDs/node
max)
|
Embedded (SATA only) or
P212, P410 or P812 (SATA/SAS)
|
| 2x2U nodes with 16SFF HDD cage (8 HDDs/node
max)
|
P410 or P812 (SATA/SAS)
|
| 2x2U nodes with 24SFF HDD cage (12
HDDs/node max)
|
P410 or P812 (SATA/SAS) and
SAS Expander
|
|
|
| HP Smart Array P410/ZM 2-ports
Int PCIe x8 FIO SAS Controller
|
462860-B21
|
Controller Cable Kits
NOTE: Required Controller Cables
for the DL2000. The Controller Cables below connect to the adapter board
and is based on the controller used. (If using a configurator, these cable
kits will automatically be included based on controller selection.) For
a complete list of HP Controller Cable Kits, please see the Additional Options
section of this QuickSpecs. Only FIO options are mentioned here.
|
|
HP DL170e G6 Smart Array P410
Controller Cable Kit
NOTE: Supports SAS and SATA drives
when using Smart Array P410 Controller.
|
612206-B21
|
HP DL170e G6 Smart Array Controller
Cable Kit
NOTE: Supports SAS and SATA drives
when using any Smart Array Controller other than the Smart Array P410 Controller.
|
612207-B21
|
| Optional Upgrades
|
|
| HP Smart Array Hot Plug Advance
Pack for B110i w/1y 24x7 Supp Physical 1 Svr LTU
|
TC421A
|
|
| Step 4: Choose Additional Options
for Factory Integration
|
| NOTE: For additional
options, please refer to the "Core Options" and "Additional
Options" section below.
|
Core Options
| NOTE: Some options
may not be integrated at the factory. To ensure only valid configurations
are ordered, HP recommends the use of an HP approved configurator. Contact
your local sales representative for additional information.
|
| HP Unique Options
|
HP DL170e G6 Smart Array P410
Controller Cable Kit
NOTE: This cable kit is only required
when upgrading with a Smart Array P410 Controller after initial purchase.
NOTE: Supports SAS and SATA drives when using Smart Array P410 Controller.
|
612206-B21
|
HP DL170e G6 Smart Array Controller
Cable Kit
NOTE: This cable kit is only required
when upgrading with any Smart Array Controller other than the P410 after
initial purchase.
NOTE: Supports SAS and SATA drives when using any Smart Array Controller
other than the Smart Array P410 Controller.
|
612207-B21
|
HP DL170e G6 Graphics Processing
Unit Adapter Card Kit
NOTE: This kit is required when installing
a NVIDIA card in the DL170e 2U server node.
|
612253-B21
|
HP Rack Rail Shipping Bracket
Kit
NOTE: This kit is required after
initial purchase when shipping a DL2000 in a rack with 1U or more of space
above it from one location to another.
|
626167-B21
|
| HP DL2000 Server Node Servicing
Blank Kit
|
612898-B21
|
|
| HP Processors
|
Six-Core Processors
|
|
| HP DL170e G6 Intel® Xeon®
X5675 (3.06GHz/6-core/12MB/95W) Processor Kit
|
638021-B21
|
| HP DL170e G6 Intel® Xeon®
X5660 (2.80GHz/6-core/12MB/95W) Processor Kit
|
609142-B21
|
| HP DL170e G6 Intel® Xeon®
X5650 (2.66GHz/6-core/12MB/95W) Processor Kit
|
609140-B21
|
| HP DL170e G6 Intel® Xeon®
E5649 (2.53GHz/6-core/12MB/80W) Processor Kit
|
638019-B21
|
| HP DL170e G6 Intel® Xeon®
E5645 (2.40GHz/6-core/12MB/80W) Processor Kit
|
638017-B21
|
| HP DL170e G6 Intel® Xeon®
L5640 (2.26GHz/6-core/12MB/60W) Processor Kit
|
609132-B21
|
| Quad-Core Processors
|
|
| HP DL170e G6 Intel® Xeon®
E5620 (2.40GHz/4-core/12MB/80W) Processor Kit
|
609136-B21
|
| HP DL170e G6 Intel® Xeon®
L5630 (2.13GHz/4-core/12MB/40W) Processor Kit
|
612468-B21
|
| HP DL170e G6 Intel® Xeon®
E5607 (2.26GHz/4-core/8MB/80W) Processor Kit
|
638015-B21
|
| HP DL170e G6 Intel® Xeon®
E5603 (1.60GHz/4-core/4MB/80W) Processor Kit
|
638013-B21
|
|
|
HP Memory
|
Registered DIMMs
(RDIMMs)
|
|
| HP 2GB (1x2GB) Dual Rank x8 PC3-10600
(DDR3-1333) Registered CAS-9 Memory Kit
|
500656-B21
|
| HP
4GB (1x4GB) Dual Rank x4 PC3-10600 (DDR3-1333) Registered CAS-9 Memory Kit
|
500658-B21
|
| HP 4GB (1x4GB) Single Rank x4
PC3-10600 (DDR3-1333) Registered CAS-9 Memory Kit
|
593339-B21
|
HP 4GB (1x4GB) Single Rank x4
PC3L-10600 (DDR3-1333) Registered CAS-9 Low Power Memory Kit
NOTE:
Low Voltage DIMMs can only be used with Intel® Xeon® processor 5600 series
processors.
|
604504-B21
|
| HP 16GB (1x16GB) Quad Rank x4
PC3-8500 (DDR3-1066) Registered CAS-7 Memory Kit
|
500666-B21
|
| HP 8GB (1x8GB) Dual Rank x4 PC3-10600
(DDR3-1333) Registered CAS-9 Memory Kit
|
500662-B21
|
HP 8GB (1x8GB) Dual Rank x4 PC3L-10600
(DDR3-1333) Registered CAS-9 Low Power Memory Kit
NOTE:
Low Voltage DIMMs can only be used with Intel® Xeon® processor 5600 series
processors.
|
604506-B21
|
Unbuffered with ECC DIMMs (UDIMMs)
NOTE: Maximum 12 DIMMs supported per node.
|
|
| HP 2GB (1x2GB) Dual Rank x8 PC3-10600
(DDR3-1333) Unbuffered CAS-9 Memory Kit
|
500670-B21
|
| HP 4GB (1x4GB) Dual Rank x8 PC3-10600
(DDR3-1333) Unbuffered CAS-9 Memory Kit
|
500672-B21
|
| HP 4GB (1x4GB) Dual Rank x8 PC3L-10600
(DDR3-1333) Unbuffered CAS-9 Low Power Memory Kit
|
619488-B21
|
NOTE: All DDR3
memory option kits consist of one DIMM per kit. For detailed memory configuration
rules and guidelines, please use the Online DDR3 Memory Configuration Tool: www.hp.com/go/ddr3memory-configurator.
NOTE: Kits described as LV include Low Power DIMMs. For more information
on ProLiant Energy Efficient Features, see: www.hp.com/go/proliant-energy-efficient
NOTE: PC3L is a low voltage memory.
NOTE: Memory DIMM blanks
are required in any empty DIMM slots for proper cooling. If DIMMs are removed
or the memory configuration is changed, all DIMM slots must be populated with
either a blank or a DIMM.
|
|
|
NOTE: There is a maximum support limitation of 8 ranks per memory channel
(maximum of 2 quad rank DIMMs per channel)
NOTE: Memory Min and Max
depends on number of processors and type of memory:
- Processor ->
R-Dimm: Min 1 // Max 8 U-Dimm: Min 1 // Max 6
- Processors -> R-Dimm:
Min 2 // Max 16 U-Dimm: Min 2 // Max 12
|
|
|
|
HP Hard Drives
|
NOTE:
The components of a storage subsystem (e.g. the drive, the HBA/controller, firmware,
and the server backplane) should operate at the same data transfer rate or the
system bandwidth will be negotiated down to an acceptable level for all components.
NOTE: Hard drives have either a one year or three year warranty; refer
to the specific hard drive QuickSpecs for details.
NOTE: To support
HP hard drives exceeding 2.2 TB, HP Smart Array Firmware version 5.0 or later
is required for the following controllers:
- HP Smart Array P212 Controller
- HP Smart Array P410 Controller
- HP Smart Array P411 Controller
- HP Smart
Array P812 Controller
To use hard drives exceeding 2.2 TB, you must
create a boot volume using offline ACU version 8.75 or later. HP Smart Array controllers
do not support boot volumes exceeding 2.2 TB.
Other controllers are not supported.
|
|
| SAS Hot Plug SFF (2.5-inch) Enterprise
(ENT) Drives
|
|
| HP 900GB 6G SAS 10K rpm SFF (2.5-inch)
Dual Port Enterprise 3yr Warranty Hard Drive
|
619291-B21
|
| HP 600GB 6G SAS 10K rpm SFF (2.5-inch)
Dual Port Enterprise 3yr Warranty Hard Drive
|
581286-B21
|
| HP 450GB 6G SAS 10K
rpm SFF (2.5-inch) Dual Port Enterprise 3yr Warranty Hard Drive
|
581284-B21
|
| HP 300GB 6G SAS 10K rpm SFF (2.5-inch)
Dual Port Enterprise 3yr Warranty Hard Drive
|
507127-B21
|
| HP 300GB 6G SAS 15K rpm SFF
(2.5-inch) Hot Plug Enterprise 3yr Warranty Hard Drive
|
627117-B21
|
| HP 146GB 6G SAS 15K rpm SFF (2.5-inch)
Dual Port Enterprise 3yr Warranty Hard Drive
|
512547-B21
|
| SAS Hot Plug LFF (3.5-inch) Enterprise
(ENT) Drives
|
|
| HP 600GB 6G SAS 15K rpm LFF (3.5-inch)
Dual Port Enterprise 3yr Warranty Hard Drive
|
516828-B21
|
| HP
450GB 6G SAS 15K rpm LFF (3.5-inch) Dual Port Enterprise 3yr Warranty Hard Drive
|
516816-B21
|
| HP
300GB 6G SAS 15K rpm LFF (3.5-inch) Dual Port Enterprise 3yr Warranty Hard Drive
|
516814-B21
|
| SAS Hot Plug SFF (2.5-inch) Midline
(MDL) Drives
|
|
| HP 1TB 6G SAS 7.2K rpm SFF (2.5-inch)
Dual Port Midline 1yr Warranty Hard Drive
|
605835-B21
|
| HP 500GB 6G SAS 7.2K rpm SFF
(2.5-inch) Dual Port Midline 1yr Warranty Hard Drive
|
507610-B21
|
| SAS Hot Plug LFF (3.5-inch) Midline
(MDL) Drives
|
|
| HP 3TB 6G SAS 7.2K rpm LFF (3.5-inch)
Midline 1yr Warranty Hard Drive
|
625031-B21
|
| HP 2TB 6G SAS 7.2K rpm LFF (3.5-inch)
Dual Port Midline 1yr Warranty Hard Drive
|
507616-B21
|
| HP 1TB 6G SAS 7.2K rpm LFF (3.5-inch)
Dual Port Midline 1yr Warranty Hard Drive
|
507614-B21
|
NOTE: Please
see the QuickSpecs for Technical Specifications and additional information:
https://h18000.www1.hp.com/products/quickspecs/12244_na/12244_na.html
|
|
| SATA Hot Plug SFF (2.5-inch)
Midline (MDL) Drives
|
|
| HP 1TB 3G SATA 7.2K rpm SFF (2.5-inch)
Hot Plug Midline 1yr Warranty Hard Drive
|
625609-B21
|
| HP 500GB 3G SATA 7.2K rpm SFF
(2.5-inch) Midline 1yr Warranty Hard Drive
|
507750-B21
|
| SATA
Hot Plug LFF (3.5-inch) Enterprise Mainstream Solid State Drives
|
|
| HP 400GB 3G SATA MLC LFF (3.5-inch)
Enterprise Mainstream 3yr Warranty Solid State Drive
|
636611-B21
|
| HP 200GB 3G SATA MLC LFF (3.5-inch)
Enterprise Mainstream 3yr Warranty Solid State Drive
|
636609-B21
|
| HP 100GB 3G SATA MLC LFF (3.5-inch)
Enterprise Mainstream 3yr Warranty Solid State Drive
|
636607-B21
|
| SATA Hot Plug LFF (3.5-inch)
Midline (MDL) Drives
|
|
| HP 3TB 3G SATA 7.2K rpm LFF (3.5-inch)
Midline 1yr Warranty Hard Drive
|
628059-B21
|
| HP 2TB 3G SATA 7.2K rpm LFF (3.5-inch)
Midline 1yr Warranty Hard Drive
|
507632-B21
|
| HP 1TB 3G SATA 7.2K rpm LFF (3.5-inch)
Midline 1yr Warranty Hard Drive
|
454146-B21
|
| HP 500GB 3G SATA 7.2K rpm LFF
(3.5-inch) Midline 1yr Warranty Hard Drive
|
458928-B21
|
NOTE: Please
see the QuickSpecs for Technical Specifications and additional information:
https://h18000.www1.hp.com/products/quickspecs/13021_na/13021_na.html
|
|
| 6G SAS ME Hot Plug SFF (2.5-inch)
Enterprise Mainstream Solid State Drives
|
|
| HP 800GB 6G SAS Mainstream Endurance
SFF 2.5-in Enterprise Mainstream 3yr Warranty Solid State Drive
|
690823-B21
|
| HP 400GB 6G SAS Mainstream Endurance
SFF 2.5-in ENT Mainstream 3yr Warranty Solid State Drive
|
690821-B21
|
| HP 200GB 6G SAS Mainstream Endurance
SFF 2.5-in Enterprise Mainstream 3yr Warranty Solid State Drive
|
690819-B21
|
| 3G SATA MLC Hot Plug SFF (2.5-inch)
Enterprise Mainstream Solid State Drives
|
|
|
HP
400GB 3G SATA MLC SFF (2.5-inch) Enterprise Mainstream
3yr Warranty Solid State Drive
|
636597-B21
|
| HP 200GB 3G SATA MLC SFF (2.5-inch)
Enterprise Mainstream 3yr Warranty Solid State Drive
|
636595-B21
|
| HP 100GB 3G SATA MLC SFF (2.5-inch)
Enterprise Mainstream 3yr Warranty Solid State Drive
|
636593-B21
|
| 6G SAS SLC Hot Plug Enterprise
Performance Solid State Drives
|
|
| HP 400GB 6G SAS SLC SFF (2.5-inch)
Enterprise Performance 3yr Warranty Solid State Drive
|
632494-B21
|
| HP 200GB 6G SAS SLC SFF (2.5-inch)
Enterprise Performance 3yr Warranty Solid State Drive
|
632492-B21
|
NOTE: Please
see the QuickSpecs for Technical Specifications and additional information:
https://h18000.www1.hp.com/products/quickspecs/14038_na/14038_na.html
|
|
|
| HP Networking
|
Gigabit Ethernet adapters
|
|
| HP NC112T PCI Express Gigabit
Server Adapter
|
503746-B21
|
| HP NC360T PCI-E Dual Port Gigabit
Server Adapter
|
412648-B21
|
| HP NC364T PCI-E Quad Port Gigabit
Server Adapter
|
435508-B21
|
| HP NC365T 4-port Ethernet Server
Adapter
|
593722-B21
|
| HP NC373F PCI-E Multifunction
1000SX Gigabit Svr Adapter
|
394793-B21
|
| HP NC373T PCI-E Multifunction
Gigabit Server Adapter
|
394791-B21
|
| HP NC382T PCI Express Dual Port
Multifunction Gigabit Server Adapter
|
458492-B21
|
10 Gigabit Ethernet Adapters
NOTE: A minimum of two Gigabytes (2 GB) of server memory is required
per each adapter.
NOTE: Direct Attach Cable (DAC) for copper environments or fiber
transceivers and cables for fiber-optic environments must be purchased separately.
|
|
| HP NC550SFP Dual Port 10GbE Server
Adapter
|
581201-B21
|
| HP NC552SFP 10Gb 2-port Ethernet
Server Adapter
|
614203-B21
|
| NOTE: Please see
the QuickSpecs for Technical Specifications and additional information:
www.hp.com/go/ProLiantNICs.
|
|
|
| HP Power Supplies
|
NOTE:
Prior to making a power supply selection it is highly recommended that
the HP Power Advisor is run to determine the right size power supply for
your server configuration. The HP Power Advisor is located at:
www.hp.com/go/hppoweradvisor
|
|
HP 1200W Common Slot Platinum
Hot Plug Power Supply Kit
|
578322-B21
|
HP 1200W Common Slot Silver Hot
Plug Power Supply Kit
|
500172-B21
|
| HP 750W Common Slot Platinum Hot
Plug Power Supply Kit
|
593831-B21
|
| NOTE: Option Kits
contain optional power supply, an IEC power cable and PDU IEC cables.
|
|
Additional Options
| NOTE:
Some options may not be integrated at the factory. To ensure only valid
configurations are ordered, HP recommends the use of an HP approved configurator.
Contact your local sales representative for additional information.
|
| HP Management Network
|
HP Multinode Dedicated Management
Port Option Kit
NOTE: Each ProLiant DL170e G6 Server
comes standard with sideband support for LO100i through the shared, system
NIC. Order this option (P/N 601818-B21) if a dedicated management network
is desired.
|
601818-B21
|
|
| HP Entry-Level Server
Management
|
HP Lights-Out 100i (LO100i) Advanced
including 1yr 24x7 Support Single Server License
|
530521-B21
|
| HP Lights-Out 100i (LO100i) Advanced
including 1yr 24x7 Support Electronic License
|
TA859AAE
|
|
NOTE:
For additional License Kits please see the Lights-Out 100i QuickSpecs at:
www.hp.com/go/lo100.
|
|
|
| HP
Insight Software
|
HP Insight
Control
|
|
HP Insight Management Media Kit
NOTE: HP Insight Management Media Kit
contains DVDs without licenses. Contains HP Systems Insight Manager, HP Insight
Control, HP Matrix Operating Environment, and Virtual Connect Enterprise Manager
software. Uses an integrated installer to perform quick and accurate software
installation and updates.
|
C6N31A
|
| HP
Insight Control Server Deployment including 1yr 24x7 Support Electronic License
|
T9082AAE
|
| HP
Insight Control Server Deployment including 1yr 24x7 Support Single Server License
|
452151-B21
|
NOTE: Electronic
and Flexible-Quantity licenses can be used to purchase multiple licenses with
a single activation key.
NOTE: Customer will receive a license entitlement
certificate. The license entitlement certificate must be redeemed online or via
fax in order to obtain the license activation key(s). Includes one year of 24
x 7 HP Software Technical Support and Update Service.
NOTE: Licenses
ship without media. The HP Insight Control Media Kit can be ordered separately,
or can be downloaded at: https://www.hp.com/go/insightupdates.
NOTE:
For additional license options please see the QuickSpecs at: https://h18000.www1.hp.com/products/quickspecs/12631_na/12631_na.html
|
|
| HP Integrated Lights-Out (iLO)
Advanced for ProLiant
|
|
| HP iLO Advanced including 1yr
24x7 Technical Support and Updates Electronic License
|
E6U59ABE
|
| HP iLO Advanced including 3yr
24x7 Tech Support and Updates Electronic License
|
E6U64ABE
|
|
NOTE:
For additional license options please see the QuickSpecs at:
https://h18004.www1.hp.com/products/quickspecs/14276_na/14276_na.html
|
|
| NOTE:
For more information, visit: https://www.hp.com/go/ilo
|
|
|
| High
Performance Clusters
|
HP Cluster
Management Utility
|
|
HP
Insight Cluster Management Utility 1yr 24x7 Flexible License
NOTE:
This part number can be used to purchase one certificate for multiple licenses
with a single activation key. Each license is for one node (server). Customer
will receive a printed end user license agreement and license entitlement certificate
via physical shipment. The license entitlement certificate must be redeemed online
in order to obtain a license key.
|
QL803B
|
HP Insight Cluster Management
Utility 3yr 24x7 Flexible License
NOTE:
These part numbers can be used to purchase one certificate for multiple licenses
and support with a single activation key. Each license is for one node (server).
Customer will receive a printed end user license agreement and license entitlement
certificate via physical shipment. The license entitlement certificate must be
redeemed online in order to obtain a license key. Customer also will receive a
support agreement.
|
BD476A
|
| HP Insight Cluster Management
Utility Media
|
BD477A
|
| NOTE: For additional
license kits please see the QuickSpecs at: https://h18004.www1.hp.com/products/quickspecs/12612_na/12612_na.html
|
|
|
| HP Graphic Options
|
NVIDIA Quadro 6000 6GB PCI-E Adapter
|
655935-B21
|
|
| HP Security
|
HP Trusted Platform Module Option
|
488069-B21
|
NOTE: The TPM
(Trusted Platform Module) is a microcontroller chip that can securely store
artifacts used to authenticate the server platform. These artifacts can
include passwords, certificates and encryption keys. Windows® BitLocker™
Drive Encryption (BitLocker) is a data protection feature available in Windows
Server® 2008. BitLocker leverages the enhanced security capabilities
of a Trusted Platform Module (TPM) version 1.2. The TPM works with BitLocker
to help protect user data and to ensure that a server running Windows Server
2008 has not been tampered with while the system was offline. For more information
about TPM, including a white paper, go to: www.hp.com/go/TPM.
NOTE: ProLiant OS pre-installed units will come with the partition
required for TPM deployment.
NOTE: The TPM key is unique to every TPM deployed server and must
be retained. Misplacing or losing the key could result in data loss.
|
|
|
| HP Storage Controllers
|
HP Smart Array P212 Controller
|
|
| HP Smart Array P212/256 1-ports
Int/1-ports Ext PCIe x8 SAS Controller
|
462834-B21
|
| HP Smart Array P212/ZM 1-ports
Int/1-ports Ext PCIe x8 SAS Controller
|
462828-B21
|
| HP Smart Array P410 Controller
|
|
| HP Smart Array P410/256 2-ports
Int PCIe x8 SAS Controller
|
462862-B21
|
| HP Smart Array P410/512 FBWC 2-ports
Int PCIe x8 SAS Controller
|
578230-B21
|
| HP Smart Array P410/1G FBWC 2-ports
Int PCIe x8 SAS Controller
|
572532-B21
|
| HP Smart Array P411 Controller
|
|
| HP Smart Array P411/256 2-ports
Ext PCIe x8 SAS Controller
|
462830-B21
|
| HP Smart Array P411/512 FBWC 2-ports
Ext PCIe x8 SAS Controller
|
578229-B21
|
| HP Smart Array P411/1G FBWC 2-ports
Ext PCIe x8 SAS Controller
|
572531-B21
|
| Smart Array P812 Controller
|
|
| HP Smart Array P812/1G FBWC 2-ports
Int/4-ports Ext PCIe x8 SAS Controller
|
487754-B21
|
| Optional Upgrades
|
|
HP DL170e G6 Smart Array P410
Controller Cable Kit
NOTE: This cable kit is only required
when upgrading with a Smart Array P410 Controller after initial purchase.
NOTE: Supports SAS and SATA drives when using Smart Array P410 Controller.
|
612206-B21
|
HP DL170e G6 Smart Array Controller
Cable Kit
NOTE: This cable kit is only required
when upgrading with any Smart Array Controller other than the P410 after
initial purchase.
NOTE: Supports SAS and SATA drives when using any Smart Array Controller
other than the Smart Array P410 Controller.
|
612207-B21
|
HP 256MB P-series Cache Upgrade
NOTE: Supported on HP Smart Array
P212 Controller only.
|
462968-B21
|
| HP 512MB Flash Backed Write Cache
|
534916-B21
|
| HP 1GB Flash Backed Cache
|
534562-B21
|
| HP Smart Array Hot Plug Advance
Pack for B110i w/1y 24x7 Supp Physical 1 Svr LTU
|
TC421A
|
NOTE: Please see
the QuickSpecs for Technical Specifications and additional information:
https://h18000.www1.hp.com/products/quickspecs/13203_na/13203_na.html
(Smart Array P212 Controller)
https://h18000.www1.hp.com/products/quickspecs/13201_na/13201_na.html
(Smart Array P410 Controller)
https://h18000.www1.hp.com/products/quickspecs/13202_na/13202_na.html
(Smart Array P411 Controller)
https://h18000.www1.hp.com/products/quickspecs/13558_na/13558_na.html
(Smart Array P812 Controller)
|
|
| SAS Controller Options
|
|
| HP 24 Bay SAS Expander Card
|
468406-B21
|
| HP Mini SAS to Mini SAS 8in Cable
Assembly
|
496012-B21
|
NOTE: Please see
the QuickSpecs for Technical Specifications and additional information:
https://h18004.www1.hp.com/products/quickspecs/13232_na/13232_na.html
(SAS Expander Card)
|
|
| SCSI HBA
|
|
| HP SC11Xe Ultra320 Single Channel/
PCIe x4 SCSI Host Bus Adapter
|
412911-B21
|
NOTE: Please see
the QuickSpecs for Technical Specifications and additional information:
https://h18000.www1.hp.com/products/quickspecs/12566_na/12566_na.html
(SCSI HBA)
|
|
|
| HP Tape Backup
|
NOTE: For the
complete range of tape drives, autoloaders, libraries and media see: https://www.hp.com/go/tape.
For hardware and software compatibility of HP tape backup products see:
https://www.hp.com/storage/SPOCK
|
|
| HP StoreEver LTO-6 Ultrium 6250
Tape Drive in 1U Rack-mount Kit
|
C0L99A
|
| HP StoreEver LTO-6 Ultrium 6650
Internal Tape Drive
|
EH963A
|
| HP StoreEver LTO-6 Ultrium 6650
External Tape Drive
|
EH964A
|
| HP StoreEver LTO-6 Ultrium 6250
Internal Tape Drive
|
EH969A
|
| HP StoreEver LTO-6 Ultrium 6250
External Tape Drive
|
EH970A
|
|
| HP Storage Options
|
Storage
Fibre Channel HBA
|
|
| NOTE:
The following is a list of all Fibre Channel Host Bus Adapters for Windows and
Linux. For detailed compatibility information please see: https://h18006.www1.hp.com/storage/saninfrastructure/hba.html
|
|
| Brocade Fibre Channel HBAs
|
|
| HP 81B 8Gb 1-port PCIe Fibre
Channel Host Bus Adapter
|
AP769B
|
| HP 82B 8Gb 2-port PCIe Fibre
Channel Host Bus Adapter
|
AP770B
|
| Emulex Fibre Channel HBAs
|
|
| HP 81E 8Gb 1-port PCIe Fibre
Channel Host Bus Adapter
|
AJ762B
|
| HP 82E 8Gb 2-port PCIe Fibre
Channel Host Bus Adapter
|
AJ763B
|
| QLogic Fibre Channel HBAs
|
|
| HP 81Q 8Gb 1-port PCIe Fibre
Channel Host Bus Adapter
|
AK344A
|
| HP 82Q 8Gb 2-port PCIe Fibre
Channel Host Bus Adapter
|
AJ764A
|
| Converged Network Adapter
|
|
| HP CN1100E Dual Port Converged
Network Adapter
|
BK835A
|
|
| HP Uninterruptible Power
Systems
|
HP Rack-mountable UPS
|
|
| HP R1500 G3 Uninterruptible Power
Supply (UPS)
|
|
| HP R1.5kVA G3 1U NA Uninterruptible
Power System
|
AF469A
|
NOTE:
Please see the QuickSpecs for additional information:
https://h18000.www1.hp.com/products/quickspecs/14059_na/14059_na.html
|
|
| HP R/T3000 G2 Uninterruptible
Power System (UPS)
|
|
| HP R/T3000 G2 2U L530
Low Voltage NA/JP Uninterruptible Power System
|
AF466A
|
| HP R/T3000 G2 2U L620 High Voltage
NA/JP Uninterruptible Power System
|
AF467A
|
NOTE: Please see
the QuickSpecs for additional information:
https://h18000.www1.hp.com/products/quickspecs/14058_na/14058_na.html
|
|
| R5000 Uninterruptible Power
System (UPS)
|
|
| HP R5KVA 3U L630 High Voltage
NA/JP Uninterruptible Power System
|
AF460A
|
NOTE: Please see
the QuickSpecs for additional information:
https://h18000.www1.hp.com/products/quickspecs/14109_na/14109_na.html
|
|
| R7000 Uninterruptible Power
System (UPS)
|
|
| HP R7KVA 4U 50A High Voltage NA/JP
Uninterruptible Power System
|
AF462A
|
NOTE:
Please see the QuickSpecs for additional information:
https://h18000.www1.hp.com/products/quickspecs/14110_na/14110_na.html
|
|
NOTE:
For additional information on HP Uninterruptible Power Systems please go
to: www.hp.com/servers/rackups.
NOTE: For additional information on sizing your server, please reference:
https://www.upssizer.com.
NOTE:
Please see the UPS and PDU cable matrix's on the HP Power Protection and Management
page. Under Power Cords, click on the "HP Power Cord Matrix" link. That link will
list cable descriptions, requirements, and specifications for UPS and PDU units.
Please see the following link: www.hp.com/products/powercords.
|
|
|
| HP Basic Power Distribution Units
|
HP
1.9kVA 120 Volt 12 Outlet NA/JP Basic Power Distribution Unit
|
H5M54A
|
| HP 2.8kVA 120 Volt 18 Outlet
NA/JP Basic Power Distribution Unit
|
H5M55A
|
| HP
3.6kVA 200-240 Volt 12 Outlet WW Basic Power Distribution Unit
|
H5M56A
|
| HP
3.6kVA 200-240 Volt 20 Outlet WW Basic Power Distribution Unit
|
H5M57A
|
| HP
4.9kVA 208 Volt 20 Outlet NA/JP Basic Power Distribution Unit
|
H5M58A
|
| HP
4.9kVA 208 Volt 30 Outlet NA/JP Basic Power Distribution Unit
|
H5M59A
|
| HP
8.3kVA 208 Volt 36 Outlet NA/JP Basic Power Distribution Unit
|
H5M60A
|
| HP 8.6kVA 208 Volt Three Phase
18 Outlet NA/JP Basic Power Distribution Unit
|
H5M61A
|
| HP 8.6kVA 208 Volt
Three Phase 30 Outlet NA/JP Basic Power Distribution Unit
|
H5M62A
|
| HP 5.7kVA 208 Volt Three Phase
27 Outlet NA/JP Dual Voltage Basic Power Distribution Unit
|
H5M63A
|
| HP 8.6kVA 208 Volt Three Phase
30 Outlet NA/JP Dual Voltage Basic Power Distribution Unit
|
H5M64A
|
| HP 11kVA 400 Volt Three Phase
42 Outlet NA Basic Power Distribution Unit
|
H5M67A
|
| HP Hardwired 200-240 Volt 36
Outlet WW Basic Power Distribution Unit
|
H5M75A
|
| HP
13.2kVA 480 Volt Three Phase 15 Outlet NA Basic Power Distribution Unit
|
H3X07A
|
| HP
19.9kVA 480 Volt Three Phase 30 Outlet NA Basic Power Distribution Unit
|
H3X08A
|
| HP
277 Volt options for H3X07A and H3X08A
|
|
| HP
800VA - 277V Input / 230V Output NA Rack Mount Transformer
|
H3X09A
|
NOTE: Please
see the QuickSpecs for Technical Specifications and additional information:
https://h18000.www1.hp.com/products/quickspecs/14557_na/14557_na.html
|
|
| NOTE: Additional
HP Power Distribution Units are available. For a complete list of all HP PDUs
and additional information please visit www.hp.com/go/rackandpower.
|
|
|
| HP Remote Monitoring Power Distribution
Units
|
HP 2.8kVA 120 Volt 12 Outlet
NA/JP Monitored Power Distribution Unit
|
D9N43A
|
| HP 4.9kVA 208 Volt 12 Outlet
NA/JP Monitored Power Distribution Unit
|
D9N44A
|
| HP
3.6kVA 200-240 Volt 16 Outlet WW Monitored Power Distribution Unit
|
D9N45A
|
| HP
3.6kVA 200-240 Volt 12 Outlet WW Monitored Power Distribution Unit
|
D9N46A
|
| HP
4.9kVA 208 Volt 24 Outlet NA/JP Monitored Power Distribution Unit
|
D9N47A
|
| HP
8.3kVA 208 Volt 33 Outlet NA Monitored Power Distribution Unit
|
D9N49A
|
| HP 8.6kVA 208 Volt
Three Phase 21 Outlet NA/JP Monitored Power Distribution Unit
|
D9N51A
|
| HP 5.7kVA 208 Volt Three Phase
21 Outlet NA/JP Dual Voltage Monitored Power Distribution Unit
|
D9N52A
|
| HP 8.6kVA 208 Volt Three Phase
24 Outlet NA/JP Dual Voltage Monitored Power Distribution Unit
|
D9N53A
|
| HP 17.3kVA 208 Volt Three Phase
27 Outlet NA/JP Monitored Power Distribution Unit
|
D9N54A
|
| HP 14.4kVA 208 Volt Three Phase
24 Outlet NA Monitored Power Distribution Unit
|
D9N58A
|
| HP 17.3kVA 208 Volt Three Phase
24 Outlet NA/JP Monitored Power Distribution Unit
|
D9N59A
|
| HP 16.6kVA 400 Volt Three Phase
33 Outlet NA Monitored Power Distribution Unit
|
D9N61A
|
| HP
16.6kVA 400 Volt Three Phase 24 Outlet NA Monitored Power Distribution Unit
|
D9N62A
|
| HP
19.9kVA 480 Volt Three Phase 30 Outlet NA Monitored Power Distribution Unit
|
D9N63A
|
| HP
Environmental Sensor for Remote Monitored PDUs
|
|
| HP
Environmental Sensor for Remote Monitored PDUs
|
E2D53A
|
NOTE: Please
see the QuickSpecs for additional information:
https://h18000.www1.hp.com/products/quickspecs/14669_na/14669_na.html
|
|
|
| HP Intelligent Power Distribution
Units (iPDU)
|
iPDU
Core Units
|
|
|
HP
4.9kVA 24A Single Phase NA/JP Core Intelligent Modular Power Distribution
Unit
|
AF520A
|
|
HP 8.3kVA
40A Single Phase NA/JP Core Intelligent Modular Power Distribution Unit
|
AF521A
|
|
HP
8.6kVA 24A Three Phase NA/JP Core Intelligent Modular Power Distribution
Unit
|
AF522A
|
|
HP 17.3kVA
48A Three Phase NA/JP Core Intelligent Modular Power Distribution Unit
|
AF523A
|
HP 4.9kVA
24A Single Phase NA/JP Intelligent Modular Power Distribution Kit
|
AF531A
|
HP 8.6kVA
24A Three Phase NA/JP Intelligent Modular Power Distribution Kit
|
AF532A
|
HP 14.4kVA
40A Three Phase NA/JP Intelligent Modular Power Distribution Unit
|
AF533A
|
| iPDU Extension Bars
|
|
HP 5xC13
Intelligent PDU Extension Bar G2 Kit
NOTE: Intelligent Extensions
Bars have individually monitored outlets that are also individually switchable
for power cycling attached equipment. Each individual C13 outlet has Power
Line Communications to support Intelligent Power Discovery when connected
to PLC enabled common slot power supplies.
|
AF547A
|
HP 5xC13
Outlets Power and UID LEDs Pair Standard Extension Bar
NOTE: Standard (non-intelligent)
Extension Bars are monitored as a single load segment and do not support
Intelligent Power Discovery.
|
AF528A
|
NOTE:
Extension Bars can be mixed on a PDU core to create custom configurations.
Up to 6 extension bars may be added to each Intelligent PDU Core unit.
NOTE: For additional information on the HP Intelligent PDU please
go to: www.hp.com/go/ipdu
NOTE: Double stick mounting brackets for the Standard Extension Bars
cannot be used in DL2000 installations.
NOTE: Please see the QuickSpecs for
Technical Specifications and additional information:
https://h18000.www1.hp.com/products/quickspecs/13650_na/13650_na.html
|
|
|
|
HP Power Distribution Units
|
HP
Monitored Power Distribution Unit: Full Rack Version
|
|
| HP
8.6kVA 24A Single Input Three Phase NA/JP Monitored Power Distribution Unit
|
AF504A
|
| HP
8.3kVA 40A Single Input Single Phase NA/JP Monitored Power Distribution Unit
|
AF506A
|
| HP Monitored Power Distribution
Unit: Half Rack Version
|
|
| HP 4.9kVA 24A Single
Input Single Phase NA/JP Monitored Power Distribution Unit
|
AF914A
|
NOTE: Please
see the following QuickSpecs for additional information:
https://h18000.www1.hp.com/products/quickspecs/12118_na/12118_na.html
|
|
NOTE:
Please see the UPS and PDU cable matrix's on the HP Power Protection and Management
page. Under Power Cords, click on the "HP Power Cord Matrix" link. That link will
list cable descriptions, requirements, and specifications for UPS and PDU units.
Please see the following link: www.hp.com/products/powercords
NOTE:
For additional information on HP Power Distribution Units including accessories
please go to: www.hp.com/go/pdu
|
|
|
| HP Rack Series
|
HP Intelligent Series Rack
|
|
| HP 642 1075mm Pallet Intelligent
Series Rack
|
BW903A
|
| HP 642 1075mm Shock Intelligent
Series Rack
|
BW904A
|
NOTE: Please see
the QuickSpecs for Technical Specifications such as height, width, depth,
weight, and color:
https://h18000.www1.hp.com/products/quickspecs/14223_na/14223_na.html
NOTE: For additional information regarding Rack Cabinets, please
see the following URL: https://www.hp.com/go/rackandpower.
|
|
|
|
HP Rack Options
|
HP TFT7600 G2 KVM Console and
Monitor (TFT7600 G2)
|
|
| HP TFT7600 G2 KVM Console Rackmount
Keyboard US Monitor
|
AZ870A
|
| HP TFT7600 G2 KVM Console Rackmount
Keyboard US TAA Monitor
|
AZ885A
|
NOTE: Please see
the QuickSpecs for Technical Specifications and additional information:
https://h18000.www1.hp.com/products/quickspecs/13731_na/13731_na.html
|
|
| HP USB Keyboard and Mouse
|
|
| HP USB BFR with PVC Free US Keyboard/Mouse
Kit
|
631341-B21
|
NOTE: Please see
the QuickSpecs for Technical Specifications and additional information:
https://h18000.www1.hp.com/products/quickspecs/13972_na/13972_na.html
|
|
| HP Server Console Switches
|
|
| HP Server Console 0x2x8 Port Analog
Switch
|
AF616A
|
| HP Server Console 0x2x16 Port
Analog Switch
|
AF617A
|
| HP TAA 0x2x16xKVM Server Console
G2 Switch
|
AF626A
|
NOTE: Please see
the QuickSpecs for Technical Specifications and additional information:
https://h18000.www1.hp.com/products/quickspecs/11834_na/11834_na.html
|
|
| HP Server Console Switch G2
with Virtual Media & CAC
|
|
| HP 0x2x16 KVM Server Console Switch
G2 with Virtual Media CAC Software
|
AF618A
|
| HP 0x2x32 KVM Server Console Switch
G2 with Virtual Media CAC Software
|
AF619A
|
| HP KVM CAT5 1-pack USB Interface
Adapter
|
336047-B21
|
NOTE: Please see
the QuickSpecs for Technical Specifications and additional information:
https://h18000.www1.hp.com/products/quickspecs/13475_na/13475_na.html
|
|
| HP IP Console Switch G2 with
Virtual Media & CAC
|
|
| HP 1x4 USB/PS2 KVM Console Switch
|
AF611A
|
| HP 1x1Ex8 KVM IP Console Switch
G2 with Virtual Media CAC Software
|
AF620A
|
| HP 2x1Ex16 KVM IP Console Switch
G2 with Virtual Media CAC Software
|
AF621A
|
| HP 4x1Ex32 KVM IP Console Switch
G2 with Virtual Media CAC Software
|
AF622A
|
NOTE: Please see
the QuickSpecs for Technical Specifications and additional information:
https://h18000.www1.hp.com/products/quickspecs/13474_na/13474_na.html
|
|
| Rail Kits
|
|
HP Rack Rail Shipping Bracket
Kit
NOTE: This kit is required after
initial purchase when shipping a DL2000 in a rack with 1U or more of space
above it from one location to another.
|
626167-B21
|
|
Memory
| HP ProLiant DL170e
G6 Server
|
| NOTE:
Memory configurations show Maximum Memory population.
|
Maximum Memory
Up to 192GB, using PC3-8500R DDR3 Registered (RDIMM) memory, operating at
800MHz when fully populated at 2 DIMMs per Channel in 12 slots
Up to 48GB, using PC3-10600E DDR3 Unbuffered (UDIMM) memory, operating at
1333MHz when fully populated at 2 DIMMs per Channel in 12 slots
NOTE: RDIMMs and UDIMMs cannot be
in the same system so the maximum RDIMM memory configuration can only be
achieved with BTO models by replacing all of the UDIMMs.
|
| NOTE:
Chart does not represent all possible memory configurations.
|
|
DDR3 memory population guidelines
For detailed memory configuration rules and guidelines, please use the
Online DDR3 Memory Configuration Tool: www.hp.com/go/ddr3memory-configurator
- Some DIMM installation guidelines are summarized below:
- Memory DIMM blanks are required in any empty DIMM slots for proper
cooling. If DIMMs are removed or the memory configuration is changed,
all DIMM slots must be populated with either a blank or a DIMM.
- For servers with sixteen (16) memory slots
- There are three (3) channels per processor; six (6) channels per server
- There are two (3) DIMM slots for two memory channels and one (2) DIMM
slots for one memory channel; sixteen (16) total slots
- Memory channel 1 consists of the two (2) DIMM slots that are closest
to the processor
- Memory channels 2 and 3 consist of the six (6) DIMM slots that are
furthest from the processor
- DIMM slots that are white should be populated first
- Do not mix Unbuffered memory (UDIMMs) with Registered memory (RDIMMs)
- Do not install DIMMs if the corresponding processor is not installed
- If only one processor is installed in a 2CPU system, only half of
the DIMM slots are available
- To maximize performance, balance the total memory capacity between
all installed processors
- It is not required, but it is recommended to load the channels similarly
if possible
- You can only have up to eight (8) ranks installed per channel
- You can only install two quad-rank DIMMs per channel
- You can only install two UDIMMs per channel; if available, the third
slot in the channel must remain empty
- Populate DIMMs from heaviest load (quad-rank) to lightest load (single-rank)
within a channel
- Heaviest load (DIMM with most ranks) within a channel goes furthest
from the chipset
- Low Voltage DIMMs can only be used with Intel Xeon 5600 series processors.
- For memory mirroring mode, channel 3 must be unpopulated. Channels
1 and 2 are populated identically
- For lock-step mode, channel 3 must be unpopulated. DIMMs in channels
1 and 2 will be installed in pairs. The paired slots will be 1,4; 2,5;
3;6 on a 3DPC system or 1,4; 2,5; on a 2DPC system
- If mixing DIMM voltage is a requirement, please note that the DIMMs
will run at 1.5V since all 1.35V are capable of supporting 1.5V operations.
|
|
|
| DIMM Type ->
|
Registered
DIMMs (RDIMMs)
|
Unbuffered
with ECC DIMMs (UDIMMs)
|
| DIMM Rank ->
|
Single
Rank
(1R)
|
Dual Rank
(2R)
|
Quad Rank
(4R)
|
Single
Rank
(1R)
|
Dual Rank
(2R)
|
| DIMM Capacity ->
|
4GB
|
2GB
|
4GB
|
8GB
|
8GB
|
16GB
|
4GB
|
16GB
|
1GB
|
2GB
|
4GB
|
| DIMM Native Speed (MHz) ->
|
1333
|
1333
|
1333
|
1066
|
1333
|
1333
|
1066
|
1066
|
1333
|
1333
|
1333
|
| Voltage
|
LV/Std
|
Std
|
Std
|
Std
|
LV/Std
|
LV/Std
|
Std
|
Std
|
Std
|
Std
|
LV/Std
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| SLOTS THAT CAN BE POPULATED
|
| 16 slot servers
|
16
|
16
|
16
|
16
|
16
|
16
|
12
|
12
|
12
|
12
|
12
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| MAXIMUM MEMORY CAPACITY
(GB)
|
| 16 slot servers
|
64
|
32
|
64
|
128
|
128
|
256
|
48
|
192
|
12
|
24
|
48
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| POPULATED DIMM SPEED (MHz)
|
| 1 DIMM Per Channel
|
1333
|
1333
|
1333
|
1066
|
1333
|
1333
|
1066
|
1066
|
1333
|
1333
|
1333
|
| 2 DIMMs Per Channel
|
1333
*
|
1333
*
|
1333
*
|
1066
|
1333
*
|
1066/
1333
**
|
800
|
800
|
1066
|
1066
|
1333
*
|
| 3 DIMMs Per Channel (on 2 channels)
|
800
|
800
|
800
|
800
|
800
|
800
***
|
N/A
|
N/A
|
N/A
|
N/A
|
N/A
|
|
*supported with ROM update via ROM
Based Setup Utility (RBSU)
** 2DPC: LV runs at 1066, Std voltage runs at 1333
***3DPC: LV/Std voltage runs at 800
|
|
NOTES:
- PC3-10600 DIMMs have a maximum speed of 1333MHz. PC3-8500 DIMMs have
a maximum speed of 1066MHz
- Mixing DIMM speeds is allowed, but the system processor speed rules
always override the DIMM capabilities
- If you do mix DIMM speeds, the memory bus will default to the minimum
clock rate of all DIMMs in the system - even if the slower DIMM is on
the other processor
- If you install 1x 1066MHz DIMM in channel 1 and 1x 1333MHz DIMM in
channel 2, the maximum speed will be 1066MHz If you install 1x 1066MHz
DIMM in channel 1 and 5x 1333MHz DIMMs with 1 DIMM Per Channel (DPC)
in each of the other channels, the maximum speed will be 1066MHz
- If you install 3DPC in one channel (if applicable) and 1DPC in all
other channels, you run at 800MHz
- Maximum memory speed will also depend on the processor installed
- References to the above MHz speeds are for the various speeds of DDR3
DIMMs; 1333 refers to DDR3-1333, etc.
|
|
|
|
DIMM slot and configuration diagrams
Basic memory slot & population diagram
- Population order; start with "A" first, "B" second,
"C" third, etc. DIMM 8 is DIMM furthest away from the CPU
and DIMM 1 is DIMM closest to CPU.
|
|
|
CPU1
|
CPU2
|
|
|
|
slot #
|
population order
|
slot #
|
population order
|
|
| Chnl 1
|
1
|
A
|
1
|
A
|
Chnl 1
|
| 2
|
D
|
2
|
D
|
| 3
|
G
|
3
|
G
|
|
|
|
|
|
|
|
| Chnl 2
|
4
|
B
|
4
|
B
|
Chnl 2
|
| 5
|
E
|
5
|
E
|
| 6
|
H
|
6
|
H
|
|
|
|
|
|
|
|
| Chnl 3
|
7
|
C
|
7
|
C
|
Chnl 3
|
| 8
|
F
|
8
|
F
|
|
|
|
|
RDIMM maximum configuration (2 CPUs)
- 192GB, consisting of sixteen (16) 16GB quad rank PC3-8500 RDIMMs
|
|
|
CPU1
|
CPU2
|
|
|
|
slot #
|
population order
|
slot #
|
population order
|
|
| Chnl 1
|
1
|
A; 16GB DIMM
|
1
|
A; 16GB DIMM
|
Chnl 1
|
| 2
|
D; 16GB DIMM
|
2
|
D; 16GB DIMM
|
| 3
|
G; empty
|
3
|
G; empty
|
|
|
|
|
|
|
|
| Chnl 2
|
4
|
B; 16GB DIMM
|
4
|
B; 16GB DIMM
|
Chnl 2
|
| 5
|
E; 16GB DIMM
|
5
|
E; 16GB DIMM
|
| 6
|
H; empty
|
6
|
H; empty
|
|
|
|
|
|
|
|
| Chnl 3
|
7
|
C; 16GB DIMM
|
7
|
C; 16GB DIMM
|
Chnl 3
|
| 8
|
F; 16GB DIMM
|
8
|
F; 16GB DIMM
|
|
|
|
|
UDIMM maximum configuration (2 CPUs)
- 48GB, consisting of twelve (12) 2GB dual-rank PC3-10600 UDIMMs
|
|
|
CPU1
|
CPU2
|
|
|
|
slot #
|
population order
|
slot #
|
population order
|
|
| Chnl 1
|
1
|
A; 4GB DIMM
|
1
|
A; 4GB DIMM
|
Chnl 1
|
| 2
|
D; 4GB DIMM
|
2
|
D; 4GB DIMM
|
| 3
|
G; empty
|
3
|
G; empty
|
|
|
|
|
|
|
|
| Chnl 2
|
4
|
B; 4GB DIMM
|
4
|
B; 4GB DIMM
|
Chnl 2
|
| 5
|
E; 4GB DIMM
|
5
|
E; 4GB DIMM
|
| 6
|
H; empty
|
6
|
H; empty
|
|
|
|
|
|
|
|
| Chnl 3
|
7
|
C; 4GB DIMM
|
7
|
C; 4GB DIMM
|
Chnl 3
|
| 8
|
F; 4GB DIMM
|
8
|
F; 4GB DIMM
|
|
|
|
|
NOTE: Capacity references are rounded to the common Gigabyte values.
- 1GB = 1024MB
- 2GB = 2048MB
- 4GB = 4096MB
- 8GB = 8192MB
- 16GB = 16384MB
|
|
DDR3 memory options part number decoder
|
|
|
|
|
Following are memory options available from HP:
|
| HP
Memory
|
Registered DIMMs (RDIMMs)
|
|
| HP 2GB (1x2GB) Dual Rank x8 PC3-10600
(DDR3-1333) Registered CAS-9 Memory Kit
|
500656-B21
|
| HP
4GB (1x4GB) Dual Rank x4 PC3-10600 (DDR3-1333) Registered CAS-9 Memory Kit
|
500658-B21
|
| HP
4GB (1x4GB) Single Rank x4 PC3-10600 (DDR3-1333) Registered CAS-9 Memory Kit
|
593339-B21
|
HP 4GB (1x4GB) Single Rank x4
PC3L-10600 (DDR3-1333) Registered CAS-9 Low Power Memory Kit
NOTE:
Low Voltage DIMMs can only be used with Intel® Xeon® processor 5600 series
processors.
|
604504-B21
|
| HP 16GB (1x16GB) Quad Rank x4
PC3-8500 (DDR3-1066) Registered CAS-7 Memory Kit
|
500666-B21
|
| HP 8GB (1x8GB) Dual Rank x4 PC3-10600
(DDR3-1333) Registered CAS-9 Memory Kit
|
500662-B21
|
HP 8GB (1x8GB) Dual Rank x4 PC3L-10600
(DDR3-1333) Registered CAS-9 Low Power Memory Kit
NOTE:
Low Voltage DIMMs can only be used with Intel® Xeon® processor 5600 series
processors.
|
604506-B21
|
Unbuffered with ECC DIMMs (UDIMMs)
NOTE: Maximum 12 DIMMs supported per node.
|
|
| HP 2GB (1x2GB) Dual Rank x8 PC3-10600
(DDR3-1333) Unbuffered CAS-9 Memory Kit
|
500670-B21
|
| HP 4GB (1x4GB) Dual Rank x8 PC3-10600
(DDR3-1333) Unbuffered CAS-9 Memory Kit
|
500672-B21
|
| HP 4GB (1x4GB) Dual Rank x8 PC3L-10600
(DDR3-1333) Unbuffered CAS-9 Low Power Memory Kit
|
619488-B21
|
NOTE: All DDR3
memory option kits consist of one DIMM per kit. For detailed memory configuration
rules and guidelines, please use the Online DDR3 Memory Configuration Tool: www.hp.com/go/ddr3memory-configurator.
NOTE: Kits described as LV include Low Power DIMMs. For more information
on ProLiant Energy Efficient Features, see: www.hp.com/go/proliant-energy-efficient
NOTE: PC3L is a low voltage memory.
|
|
|
NOTE: There
is a maximum support limitation of 8 ranks per memory channel (maximum of 2 quad
rank DIMMs per channel)
NOTE: Memory Min and Max depends on number
of processors and type of memory:
- Processor -> R-Dimm: Min 1 //
Max 8 U-Dimm: Min 1 // Max 6
- Processors -> R-Dimm: Min 2 // Max 16
U-Dimm: Min 2 // Max 12
|
|
Storage
|
Drive Support
|
|
| Removable Media
|
|
|
|
|
|
Quantity
Supported
|
Position
Supported
|
Controller
|
|
DVD-ROM
|
Up to 2 per node
|
External
|
USB
|
| DVD/CD RW
|
Up to 2 per node
|
External
|
USB
|
|
|
Hard Drives
NOTE: The components of a storage
subsystem (e.g. the drive, the HBA/controller, firmware, and the server
backplane) should operate at the same data transfer rate or the system
bandwidth will be negotiated down to an acceptable level for all components.
NOTE: Hard drives have either a one year or three year warranty;
refer to the specific hard drive QuickSpecs for details.
NOTE: To support HP hard drives exceeding 2.2 TB, HP Smart Array
Firmware version 5.0 or later is required for the following controllers:
-
HP Smart Array P212 Controller
-
HP Smart Array P410 Controller
-
HP Smart Array P411 Controller
-
HP Smart Array P812 Controller
To use hard drives exceeding 2.2 TB,
you must create a boot volume using offline ACU version 8.75 or later.
HP Smart Array controllers do not support boot volumes exceeding 2.2 TB.
Other controllers are not supported.
|
| SAS Hot Plug SFF (2.5-inch)
Enterprise (ENT) Drives
|
|
|
Quantity
Supported
|
Position
Supported
|
Controller
|
|
900GB 6G SAS 10K
600GB 6G SAS 10K
450GB 6G SAS 10K
300GB 6G SAS 10K
300GB 6G SAS 15K
146GB 6G SAS 15K
|
24
|
1-24
|
HP Smart Array P212/Zero Memory
Controller
HP Smart Array P212/256 MB Controller
HP Smart Array P410/256 MB Controller
HP Smart Array P410/512 MB BBWC Controller
|
|
| SAS Hot Plug LFF (3.5-inch)
Enterprise (ENT) Drives
|
|
|
Quantity
Supported
|
Position
Supported
|
Controller
|
600GB 6G SAS 15K
450GB 6G SAS 15K
300GB 6G SAS 15K
|
Up to 8
|
1-8
|
HP Smart Array P212/Zero Memory
Controller
HP Smart Array P212/256 MB Controller
HP Smart Array P410/256 MB Controller
HP Smart Array P410/512 MB BBWC Controller
|
|
| SAS Hot Plug SFF (2.5-inch) Midline
(MDL) Drives
|
|
|
Quantity
Supported
|
Position
Supported
|
Controller
|
1TB 6G SAS 7.2K
500GB 6G SAS 7.2K
|
Up to 24
|
1-24
|
HP Smart Array P212/Zero Memory
Controller
HP Smart Array P212/256 MB Controller
HP Smart Array P410/256 MB Controller
HP Smart Array P410/512 MB BBWC Controller
|
|
| SAS Hot Plug LFF (3.5-inch)
Midline (MDL) Drives
|
|
|
Quantity
Supported
|
Position
Supported
|
Controller
|
2TB 6G SAS 7.2K
1TB 6G SAS 7.2K
|
Up to 8
|
1-8
|
HP Smart Array P212/Zero Memory
Controller
HP Smart Array P212/256 MB Controller
HP Smart Array P410/256 MB Controller
HP Smart Array P410/512 MB BBWC Controller
|
|
| SATA Hot Plug SFF
(2.5-inch) Midline (MDL) Drives
|
|
|
Quantity
Supported
|
Position
Supported
|
Controller
|
1TB 3G SATA 7.2K
500GB 3G SATA 7.2K
|
24
|
1-24
|
Embedded HP Smart Array Hot Plug
Advanced Pack for B110i (RAID 0, 1, 10)
HP Smart Array P212/Zero Memory Controller
HP Smart Array P212/256 MB Controller
HP Smart Array P410/256 MB Controller
HP Smart Array P410/512 MB BBWC Controller
|
|
| SATA Hot Plug LFF
(3.5-inch) Midline (MDL) Drives
|
|
|
Quantity
Supported
|
Position
Supported
|
Controller
|
2TB 3G SATA 7.2K
1TB 3G SATA 7.2K
500GB 3G SATA 7.2K
|
Up to 8
|
1-8
|
Embedded HP Smart Array Hot Plug
Advanced Pack for B110i (RAID 0, 1, 10)
HP Smart Array P212/Zero Memory Controller
HP Smart Array P212/256 MB Controller
HP Smart Array P410/256 MB Controller
HP Smart Array P410/512 MB BBWC Controller
|
|
| SATA Hot Plug 3.5"
Midline (MDL) Solid State Drives
|
|
|
Quantity
Supported
|
Position
Supported
|
Controller
|
120GB 3.0G SATA
60GB 3.0G SATA
|
Up to 8
|
1-8
|
Embedded HP Smart Array Hot Plug
Advanced Pack for B110i (RAID 0, 1, 10)
HP Smart Array P212/Zero Memory Controller
HP Smart Array P212/256 MB Controller
HP Smart Array P410/256 MB Controller
HP Smart Array P410/512 MB BBWC Controller
|
|
| 6G SAS Hot Plug Enterprise
Performance Solid State Drives
|
|
|
Quantity
Supported
|
Position
Supported
|
Controller
|
200GB 6G SAS SLC SFF
400GB 6G SAS SLC SFF
|
24
|
1-24
|
HP Smart Array P212/Zero Memory
Controller
HP Smart Array P212/256 MB Controller
HP Smart Array P410/256 MB Controller
HP Smart Array P410/512 MB BBWC Controller
|
Power Specifications
| HP 750W Common Slot Platinum
Hot Plug Power Supply Kit
|
| Part Number
|
593831-B21
|
| Input Voltage Range ( V rms )
|
100 to 240
|
| Frequency Range (Nominal) ( Hz )
|
50/60
|
| Nominal Input Voltage ( Vrms )
|
100
|
120
|
200
|
208
|
220
|
230
|
240
|
| Maximum Rated Output Wattage Rating
|
750
|
750
|
750
|
750
|
750
|
750
|
750
|
| Nominal Input Current ( A rms )
|
8.6
|
7.1
|
4.2
|
4.0
|
3.8
|
3.6
|
3.4
|
| Maximum Rated Input Wattage Rating
( Watts )
|
841
|
828
|
809
|
808
|
807
|
806
|
805
|
| Maximum Rated VA ( Volt-Amp )
|
863
|
850
|
830
|
829
|
828
|
827
|
826
|
| Efficiency ( % )
|
89.2
|
90.6
|
92.7
|
92.8
|
93
|
93.1
|
93.2
|
| Power Factor
|
0.985
|
| Leakage Current ( mA )
|
0.42
|
0.50
|
0.83
|
0.87
|
0.92
|
0.96
|
1.00
|
| Maximum Inrush Current ( A peak )
|
30
|
| Maximum Inrush Current duration ( mS
)
|
20
|
| Maximum British Thermal Unit Rating
( BTU-Hr )
|
2868
|
2825
|
2761
|
2757
|
2753
|
2749
|
2747
|
|
|
|
| HP 1200W Common Slot Platinum
Hot Plug Power Supply Kit
|
| Part Number
|
578322-B21
|
| Input Voltage Range ( V rms )
|
100 to 240
|
| Frequency Range (Nominal) ( Hz )
|
50/60
|
| Nominal Input Voltage ( Vrms )
|
100
|
120
|
200
|
208
|
220
|
230
|
240
|
| Maximum Rated Output Wattage Rating
|
800
|
900
|
1200
|
1200
|
1200
|
1200
|
1200
|
| Nominal Input Current ( A rms )
|
9.3
|
8.6
|
6.7
|
6.5
|
6.1
|
5.8
|
5.6
|
| Maximum Rated Input Wattage Rating
( Watts )
|
889
|
989
|
1290
|
1290
|
1290
|
1290
|
1290
|
| Maximum Rated VA ( Volt-Amp )
|
927
|
1031
|
1345
|
1345
|
1345
|
1345
|
1345
|
| Efficiency ( % )
|
90
|
91
|
93
|
93
|
93
|
93
|
93
|
| Power Factor
|
0.97
|
| Leakage Current ( mA )
|
0.42
|
0.50
|
0.83
|
0.87
|
0.92
|
0.96
|
1.00
|
| Maximum Inrush Current ( A peak )
|
30
|
| Maximum Inrush Current duration ( mS
)
|
10
|
| Maximum British Thermal Unit Rating
( BTU-Hr )
|
3033
|
3375
|
4403
|
4403
|
4403
|
4403
|
4403
|
|
|
|
| HP 1200W Common Slot Silver
Hot Plug Power Supply Kit
|
| Part Number
|
500172-B21
|
| Input Voltage Range ( V rms )
|
100 to 240
|
| Frequency Range (Nominal) ( Hz )
|
50/60
|
| Nominal Input Voltage ( Vrms )
|
100
|
120
|
200
|
208
|
220
|
230
|
240
|
| Maximum Rated Output Wattage Rating
|
800
|
900
|
1200
|
1200
|
1200
|
1200
|
1200
|
| Nominal Input Current ( A rms )
|
9.7
|
9.0
|
7.0
|
6.8
|
6.4
|
6.1
|
5.9
|
| Maximum Rated Input Wattage Rating
( Watts )
|
930
|
1034
|
1348
|
1348
|
1348
|
1348
|
1348
|
| Maximum Rated VA ( Volt-Amp )
|
970
|
1079
|
1406
|
1406
|
1406
|
1406
|
1406
|
| Efficiency ( % )
|
86
|
87
|
89
|
89
|
89
|
89
|
89
|
| Power Factor
|
0.97
|
| Leakage Current ( mA )
|
0.42
|
0.50
|
0.83
|
0.87
|
0.92
|
0.96
|
1.00
|
| Maximum Inrush Current ( A peak )
|
30
|
| Maximum Inrush Current duration ( mS
)
|
20
|
| Maximum British Thermal Unit Rating
( BTU-Hr )
|
3174
|
3530
|
4600
|
4600
|
4600
|
4600
|
4600
|
|
| To review typical system power
ratings use the Active Answers HP Power Advisor which is available via the
online tool located at URL: www.hp.com/go/proliant-energy-efficient
or www.hp.com/go/hppoweradvisor
|
System Specifications
| Power
|
|
|
| ProLiant DL170e G6 Fully Configured
|
115V/60Hz
|
220V/50Hz
|
| Fully Loaded System Input Wattage
(W)
|
651
|
638
|
| Fully Loaded System Input Current
(A rms)
|
5.7
|
3.0
|
| Fully Loaded System Thermal
(BTU- Hr)
|
2218
|
2174
|
| Fully Loaded System VA
(Volt-Amp)
|
657
|
657
|
| System Leakage with all power
supplies loaded (mA)
|
1.58
|
3.03
|
| System Inrush Current with
all power supplies loaded (A)
|
19
|
37
|
| Power cord requirements
|
Nema 5-15P to IEC320-C13
|
IEC320-C13 to IEC320-C14
|
| NOTE:
Power shown is for a fully configured system consisting of (2) CPUs, (16)
DIMMs, (2) HDDs, and (1) PCI card per node.
|
| Power Cord
|
AF556A
|
|
|
|
| Server Power Cords
|
One 6' Highline (IEC-IEC) power cord ships standard
NOTE: ProLiant DL servers are primarily
connected to PDU's in data center racks so they ship standard with only
a PDU power cord (416151-B21).
NOTE: If customers require a power cord, they can check the power
cord matrix for the appropriate cord. Please see the following power cord
matrix: https://www.hp.com/go/powercordmatrix.
|
Technical Specifications
| System Unit
|
Dimensions (H x W x D)
(with bezel)
|
3.44 x 17.64 x 28.91
in (8.74 x 44.81 x 73.43 cm)
|
Weight
(approximate)
|
Maximum
(all hard drives, power supplies, and processors installed)
|
77.00 lb (34.93 kg)
|
Minimum
(one hard drive, power supply, and processor installed)
|
49.00 lb (22.22 kg)
|
Input Requirements
(per power supply)
|
Rated Line Voltage
|
90 to 140 VAC
180 to 264 VAC
|
| Rated Input Current
|
7.31A at 115VAC
3.6A at 230VAC
|
| Rated Input Frequency
|
47 to 63 Hz
|
| Rated Input Power
|
855W (at 100 VAC),
840.72W (at 200 VAC)
|
| Power Specifications
|
NOTE:
To review typical system power ratings use the HP Power Advisor which is
available online located at url:
www.hp.com/go/proliant-energy-efficient or www.hp.com/go/hppoweradvisor
|
Power Supply Output
(per power supply)
|
Rated Steady-State Power
|
653.10W (at 100 VAC),
653.08W (at 200 VAC)
|
| System Inlet Temperature
|
Operating
|
50° to 95°
F (10° to 35° C) at sea level with an altitude derating of 1.8°F
per every 1000 ft (1.0°C per every 304.8 m) above sea level to a maximum
of 10,000 ft (3048 m), no direct sustained sunlight. Maximum rate of change
is 18°F/hr (10°C/hr). The upper limit may be limited by the type
and number of options installed.
System performance may be reduced if operating with a fan fault or above
86°F (30°C).
|
| Non-operating
|
40° to 140°
F (-40° to 60° C)
Maximum rate of change is 36°F/hr (20°C/hr).
|
Relative Humidity
(non-condensing)
|
Operating
|
10% to 85% relative
humidity (Rh), 82.4°F (28°C) maximum wet bulb temperature, non-condensing.
|
| Non-operating
|
10% to 95% relative
humidity (Rh), 101.7°F (38.7°C) maximum wet bulb temperature, non-condensing.
|
| Altitude
|
Operating
|
10,000 ft (3048 m).
This value may be limited by the type and number of options installed. Maximum
allowable altitude change rate is 1500 ft/min (457 m/min).
|
| Non-operating
|
30,000 ft (9144 m).
Maximum allowable altitude change rate is 1500 ft/min (457 m/min).
|
| Acoustic Noise
|
Listed are the declared
A-Weighted sound power levels (LWAd) and declared average bystander position
A-Weighted sound pressure levels (LpAm) when the product is operating in
a 23°C ambient environment. Noise emissions were measured in accordance
with ISO 7779 (ECMA 74) and declared in accordance with ISO 9296 (ECMA 109).
The listed sound levels apply to minimally populated shipping configurations.
Additional options may result in increased sound levels.
|
| Node type
|
1U
|
2U
|
| Idle
|
|
| LWAd
|
6.4 B
|
6.5 B
|
| LpAm
|
47 dBA
|
48 dBA
|
| Operating
|
|
| LWAd
|
6.4 B
|
6.5 B
|
| LpAm
|
47 dBA
|
48 dBA
|
| Emissions Classification
(EMC)
|
FCC Rating
|
Class A
|
| Normative Standards
|
CISPR 22; EN55022;
EN55024; FCC CFR 47, Pt 15; ICES-003; CNS13438; GB9254; K22;K24; EN 61000-3-2;
EN 61000-3-3; EN 60950-1; IEC 60950-1
|
| NOTE:
Product conformance to cited product specifications is based on sample (type)
testing, evaluation, or assessment. This product or family of products is
eligible to bear the appropriate compliance logos and statements.
|
|
| HP Smart Array B110i
SATA RAID Controller
|
Simultaneous drive transfer channels
|
4 channels
|
Transfer rate synchronous
(maximum theoretical)
|
1.5 Gb/s
|
| Data transfer method
|
Intel® ICH10R
|
| Drive support
|
Serial ATA
|
| Data transfer modes
|
Legacy Mode
Combined Mode
|
| Protocol
|
Serial ATA
|
| Feature
|
NCQ (Native Command Queuing);
AHCI (Advanced Host Controller Interface)
|
| RAID levels supported
|
0, 1, 10
|
| RAID Features
|
Supports multiple logical volumes
Setup through ROM based Array Configuration Utility
Installation scripting support
NOTE: Hot-Plug functions require
the purchase of the HP Smart Array Hot Plug Advance Pack for B110i.
|
| RAID OS Support
|
Microsoft Windows Server 2003 x32
and x64 Editions
Microsoft Windows Server 2008 x32 and x64 Editions.
Red Hat Enterprise Linux 4 (x86)
Red Hat Enterprise Linux 5 (x86)
Red Hat Enterprise Linux 5 (AMD64/EM64T)
SUSE Linux Enterprise Server 10 (x86)
SUSE Linux Enterprise Server 10 (AMD64/EM64T)
SUSE Linux Enterprise Server 11 (x86)
SUSE Linux Enterprise Server 11 (AMD64/EM64T)
|
|
| Embedded NC362i PCIe
Gigabit Server Adapter
|
Network Interface
|
Integrated 10/100/1000BASE-T
Transceiver
|
| Combines a triple-speed
IEEE 802.3TM - Compliant Media Access Controller (MAC) with a triple-speed
Ethernet transceiver.
|
| Data Transfer Method
|
Compliant to x4 PCIe
Specification
|
| Controller
|
Intel® 82576
|
| Network Transfer Rate
|
10Base-T (Half-Duplex)
|
10 Mb/s
|
| 10Base-T (Full-Duplex)
|
20 Mb/s
|
| 100Base-TX (Half-Duplex)
|
100 Mb/s
|
| 100Base-TX (Full-Duplex)
|
200 Mb/s
|
| 1000Base-TX (Half and Full-Duplex)
|
2000Mb/s
|
| Connector
|
RJ-45 connector
|
| Cable Support
|
Performs all the physical
layer functions for 10BASE-T, 100BASE-T, and 1000BASE-T Ethemet on standard
Category 5 UTP
|
|
| Environment-friendly Products and
Approach
|
End-of-life Management and Recycling
|
Hewlett-Packard offers end-of-life
HP product return, trade-in, and recycling programs in many geographic areas.
For trade-in information, please go to: https://www.hp.com/go/green.
To recycle your product, please go to: https://www.hp.com/go/green
or contact your nearest HP sales office. Products returned to HP will be
recycled, recovered or disposed of in a responsible manner.
The EU WEEE directive (2002/95/EC) requires manufacturers to provide treatment
information for each product type for use by treatment facilities. This
information (product disassembly instructions) is posted on the Hewlett
Packard web site at: https://www.hp.com/go/green.
These instructions may be used by recyclers and other WEEE treatment facilities
as well as HP OEM customers who integrate and re-sell HP equipment.
|
|
|